THT-EX L1601C Скачать руководство пользователя страница 4

LED 

照明の寿命

 

LED Service Life 

60,000 hrs 

入力径

 

Entrance Hole 

1×M25 threaded holes incorporate with Cable Gland 

ケーブルグランド

 

Cable Gland (Released by a tool) 

M25×1.5 mm. Secure to Side Cover 1 with torque value 65 Nm. 
A torque with 55 Nm shall apply to the Pressure Nut to compress the Sealing 
Ring. 

ケーブル固定金具

 

Fitting Cable 
(

18/3C AWG, SOOW, 1-3 m length) 

Size of Sealing Ring 

Fitting Cable 

ID:Ø9.0, L=15 mm 

OD: Ø8.0~ Ø9.0 

取付タイプ

 

Mounting Type 
 

Wall & Hanging mounting 

 

                     

 

 

4.

 

寸法

(mm)

予告なく変更する場合が有ります。

 

Dimensions 

(All Dimensions in mm) – Subject to 

Alterations

 

 

           

         

 

5.

 

組立と設置

 

Assembly and Installation 

5.1

 

ブラケットの取付

(

照明器具は取付けの時には開けないように

 

Mounting Bracket Installation (The luminaire shall not be opened during installation) 

5.1.1

 

壁掛けおよび吊り下げ用マウントブラケット

 

Wall & Hanging Mount Bracket   

 

マウントブラケットは、壁面マウント

(

1)

と吊りマウント

(

2)

の両方に使用できます。

 

 

ブラケットホルダを配置したら付属の

 M8 

ネジを使用し

61 kgf-cm

のトルクで固定します。

 

 

壁面

/

吊り金具を構造に固定する時にはネジ等の

4

つの止め金具(付属無し)を使用します。

 

Содержание L1601C

Страница 1: ...l L1601C Revision Level 02 Date 2018 05 28 Contents 1 General Safety Instructions 2 2 Intended Field of Application 3 3 Technical Data 3 4 4 Dimension 4 5 Assembly and Installation 4 6 6 Maintenance 6...

Страница 2: ...Verify the implementation of safety instructions WARNING This manual contains basic safety instructions to be observed during installation operation and maintenance of the apparatus and for properly...

Страница 3: ...plosion Protection Dust Explosion Protection IECEx Gas Explosion Protection Dust Explosion Protection IECEx UL 18 0060X Issue 0 Ex nR IIC T6 Gc Ex tb IIIC T85 C Db DEMKO 18 ATEX 1945X Rev 0 II 3 G Ex...

Страница 4: ...y to the Pressure Nut to compress the Sealing Ring Fitting Cable 18 3C AWG SOOW 1 3 m length Size of Sealing Ring Fitting Cable ID 9 0 L 15 mm OD 8 0 9 0 Mounting Type Wall Hanging mounting 4 mm Dimen...

Страница 5: ...adjusted 5 2 Ground wire U O 4 mm 18 AWG LED 1a V 110Vac 10 M4 7 kgf cm External earth screw location as showing in the Red Circle of right pictures Ground wire cross sectional area 4 mm 18 AWG max LE...

Страница 6: ...ed are promptly detected To check as part of the maintenance schedule as following Cracks or damages on the glass cover and or on the enclosure Condition of the connecting cables Screws of the mountin...

Страница 7: ...arton box Transport Shock free in its original carton do not drop and handle carefully Store Store in a dry place in its original packaging Disposal Ensure environmentally friendly disposal of all com...

Отзывы: