ThoroughClean P13C-36C Скачать руководство пользователя страница 12

 

12 

WARNINGS & SAFETY PRECAUTIONS SPECIFIC TO THIS MACHINE: 

 

 

Never re-fuel when the engine is hot – Petrol fumes can ignite and 
explode leading to severe burns and even death! 

 

 

Use only Clean / Fresh POTABLE Water - NOT Mine recycled water.  

 

Always be conscious of High Velocity Water from this machine which can cause serious 
injury 

 

Run up and test all safety shutdowns regularly i.e. Monthly.  

 

NEVER attempt to modify levels of performance by: 

o

 

Adjusting By-Pass Valve to increase P.S.I. 

o

  Use Under-sized High Pressure Nozzles. 

 

EXTREME DANGER!

  

 

Beware of HOT engines (particularly Mufflers)  

 

Store fuels in approved containers in a well ventilated area away from heat. 

 

Never operate in a confined space – exhaust fumes are toxic!  

 

Ensure enough air flow around engine to keep it cool and to void any fumes / exhaust 
gasses.  

 

Use Specified and approved Personal Protection Equipment (PPE) for High Pressure 
Cleaners. This is a High Performance High Pressure Cleaner.  

At a Minimum wear:

  

o

  Overalls /boots /thick heavy gloves /full face protection. 

o

  Additional equipment  as instructed by site personnel or Australian regulations for 

high pressure water jetting 

 

An injury by high pressure water jets can be serious! 

 

In the event of any waterjet injury: 
 

 

Seek medical attention immediately – do not delay

 

 

Inform the doctor of the cause of the injury

 

 

Show the doctor the MEDIC ALERT information in this document or by pulling the safety 
tag off the machine and taking it with you to the doctor

 

 

Tell the doctor what type of project/task was being performed at the time of the injury 
making special note of any chemicals that were used and the quality of the water

 

 

MEDIC ALERT INFORMATION:

 

ALWAYS ENSURE MACHINE IS FITTED WITH A REMOVEABLE MEDICAL ALERT / WARNING 
TAG AND TAKE THIS TO A MEDICAL PRACTITIONER WHEN A HIGH PRESSURE WATER 
INJURY OCCURS. 

 
MEDIC ALERT INFORMATION FOR MEDICAL Practitioner’s ATTENTION:

 

This patient may be suffering from a water-jet injury. Evaluation and management should parallel 
that of a gunshot injury. The external manifestations of the injury cannot be used to predict the 
extent of internal damage. Initial management should include stabilization and a thorough 
neurovascular examination. X-rays can be used to assess subcutaneous air and foreign bodies 
distant from the site of injury. Injuries to the extremities can involve extensive nerve, muscle, vessel 
damage, as well as cause a distal compartment syndrome. Injuries to the torso can involve internal 
organ damage. Surgical consultation should be obtained. 
 
Aggressive irrigation and debridement is recommended. Surgical decompression and exploration 
may also be necessary. Angiographic studies are recommended pre-operatively if arterial injury is 
suspected. Bandages with a hygroscopic solution (MgSO4) and hyperbaric oxygen treatment have 
been used as adjunctive therapy to decrease pain, edema and subcutaneous emphysema. Unusual 
infections with uncommon organisms in immuno-compromised patients have been seen; the source 

Содержание P13C-36C

Страница 1: ...R 30C TO P20R 43C T P20R 43C TO Index Page 2 Technical data Specifications 3 4 Installation Start up 5 Operating Tips Shutting down Regular Checks 6 7 Maintenance Schedule 8 9 Trouble Shooting Guide 1...

Страница 2: ...50 psi 18 lpm Set up de rated pressure flow 1600 psi 14 lpm 3500 psi 17 lpm 2600 psi 18 lpm 3000 psi 18 lpm Or 3500psi 18 lpm 3000 psi 18 lpm Vs 3000 3500 psi Nozzle size at set up pressure 15060 1504...

Страница 3: ...To Start Ensure that the main RED ON OFF switch is switched to OFF Ensure the Choke is ON Moved fully to the left when engine is cold Ensure Fuel is OPEN Fuel lever moved all the way to the right Now...

Страница 4: ...at comfortable revs set to the power requirement for the pump pressure and flow DO NOT ALTER REMEMBER Check for leaks and Oil Levels DAILY OPERATING CLEANING TIPS 1 Using a Fan Jet first blast off hea...

Страница 5: ...ure safety protective gear is used and in good state of repair Ensure Safety MEDIC ALERT Card is handy Prolonged by pass Leaving the unit in prolonged by pass machine is switched on but trigger is not...

Страница 6: ...90 YES YES YES 10 Strip and Refurbish pump Replace Plunger Rod Oil Seals 3 pump Replace Brass Valves 6 pump Replace various seals 3 pump Replace Ceramic Piston Plungers if cracked or worn 3 pump Only...

Страница 7: ...swivels H P Hoses are usually uneconomical to repair Replace as necessary Remember to check filters regularly and clean under running water The correct procedure for replacing the filter mesh in the s...

Страница 8: ...system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the pumped water Check the tempera...

Страница 9: ...ton Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Worn or Check and Replace Seal P...

Страница 10: ...lost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Страница 11: ...r Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head face eye protection wet weather gear boots and gloves which is particularly important where hot water or aggressi...

Страница 12: ...ling the safety tag off the machine and taking it with you to the doctor Tell the doctor what type of project task was being performed at the time of the injury making special note of any chemicals th...

Страница 13: ...cement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable...

Страница 14: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Страница 15: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Страница 16: ......

Страница 17: ...spring Molla valvola 6 20 0604 00 Valve cage Gabbia valvola 6 21 1400 02 Washer Rosetta 6 5 8 4 22 1802 07 Hexagonal screw Vite M6x18 8 4 23 0205 01 Shaft protector Protezione albero 1 24 0500 09 Open...

Страница 18: ...52 0500 15 Motor flange Flangia motore 1 Part available Particolare disponibile in kit only solo in kit Part available Particolare disponibile in kit also anche in kit Part Number Description Codice...

Страница 19: ......

Страница 20: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Страница 21: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Отзывы: