ThoroughClean P13C-36C Скачать руководство пользователя страница 10

 

10 

HOW TO CAUSE EXPENSIVE DAMAGE TO YOUR MACHINE

 

WHAT WAS DONE WRONG:  WHAT WAS THE RESULT OF THIS ACTION: 

Cracked and burnt high pressure seals in pump. 

Machine was allowed to run dry 
(without water supply) 

No. 1 piston cracked due to thermal shock. 

Mechanical damages to EVERYTHING: 

-          Pistol, HP hose, pump valves, pistons 

-          Crankshaft bearing failure 

-          Pressure gauge failure 

-          By-pass valve excessive wear & tear 

-          Frequent O-rings blow outs 

Unit was run on low volume 
water supply and allowed to 
cavitate 

-          Brass heads deformed 

Over adjust by-pass valve to try 
and increase PSI 

Dump pressure was too high. Hydraulic hammer to system every 
time trigger is closed. PSI was increased 5-fold normal working 
pressure. 

Excessive wear & tear on pistons / valves / seals / HP jets. 

Excessive blocking of filters caused by bore or recycled water with 
high salt / mineral content. Pump clogged up with debris. 

In-Line filter was removed 
because “It kept blocking up!” 

Remember: Spec requirement says: “Potable water” 

Over-revved engine for more PSI 

Engine & Pump premature wear & tear. (Most increased PSI  
pressure is lost through by-pass valve and only small increase in 
pressure is achieved doing this!) Lost of waster horse power! 

When orifice is reduced, the PSI will rise and then by-pass valve will 
dump (thinking the pistol is shut). Most extra PSI will be dumped and 
only a slight increase in PSI will be achieved. 

COMMON MISTAKE:

 Put a 

smaller HP Jet onto lance for 
higher pressure.

 

Engine, By-pass valve & Pump premature wear & tear.   

Using Contaminated Fuel (“Had 
to remove fuel filter to keep 
engine running!”) 

Excess Fuel-system clean-outs required. If excessive corrosion in 
carburetor or injectors is detected after the 2nd or 3rd in-line fuel 
filter replacement, then this should ring alarm bells. 

Park machine where debris 
blows all over it. Reverse 
bulldozer over it. 

Our machines are rugged and strong – but not battle tanks! 

Hire units long-terms and fluid 
levels are not checked. 

Con-rod through the crank case! 

Modify 240 Volt electric unit to 
override thermal overload on 
motor. 

Stop-Start capacitors melted. 

Used 100m extension lead and a 
5 Kva Gen-Set. 

A 10% low current is equivalent to a 50% over-load. 

  

Our 3 hp 240 Volt motors require 8 Kva Gen-Set minimum! 

Run trucks, fork-lifts, tracked 
excavation equipment over 
hoses and lance 
assemblies/pressure guns. 

Needs replacing of damaged parts 

Содержание P13C-36C

Страница 1: ...R 30C TO P20R 43C T P20R 43C TO Index Page 2 Technical data Specifications 3 4 Installation Start up 5 Operating Tips Shutting down Regular Checks 6 7 Maintenance Schedule 8 9 Trouble Shooting Guide 1...

Страница 2: ...50 psi 18 lpm Set up de rated pressure flow 1600 psi 14 lpm 3500 psi 17 lpm 2600 psi 18 lpm 3000 psi 18 lpm Or 3500psi 18 lpm 3000 psi 18 lpm Vs 3000 3500 psi Nozzle size at set up pressure 15060 1504...

Страница 3: ...To Start Ensure that the main RED ON OFF switch is switched to OFF Ensure the Choke is ON Moved fully to the left when engine is cold Ensure Fuel is OPEN Fuel lever moved all the way to the right Now...

Страница 4: ...at comfortable revs set to the power requirement for the pump pressure and flow DO NOT ALTER REMEMBER Check for leaks and Oil Levels DAILY OPERATING CLEANING TIPS 1 Using a Fan Jet first blast off hea...

Страница 5: ...ure safety protective gear is used and in good state of repair Ensure Safety MEDIC ALERT Card is handy Prolonged by pass Leaving the unit in prolonged by pass machine is switched on but trigger is not...

Страница 6: ...90 YES YES YES 10 Strip and Refurbish pump Replace Plunger Rod Oil Seals 3 pump Replace Brass Valves 6 pump Replace various seals 3 pump Replace Ceramic Piston Plungers if cracked or worn 3 pump Only...

Страница 7: ...swivels H P Hoses are usually uneconomical to repair Replace as necessary Remember to check filters regularly and clean under running water The correct procedure for replacing the filter mesh in the s...

Страница 8: ...system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the pumped water Check the tempera...

Страница 9: ...ton Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Worn or Check and Replace Seal P...

Страница 10: ...lost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Страница 11: ...r Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head face eye protection wet weather gear boots and gloves which is particularly important where hot water or aggressi...

Страница 12: ...ling the safety tag off the machine and taking it with you to the doctor Tell the doctor what type of project task was being performed at the time of the injury making special note of any chemicals th...

Страница 13: ...cement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable...

Страница 14: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Страница 15: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Страница 16: ......

Страница 17: ...spring Molla valvola 6 20 0604 00 Valve cage Gabbia valvola 6 21 1400 02 Washer Rosetta 6 5 8 4 22 1802 07 Hexagonal screw Vite M6x18 8 4 23 0205 01 Shaft protector Protezione albero 1 24 0500 09 Open...

Страница 18: ...52 0500 15 Motor flange Flangia motore 1 Part available Particolare disponibile in kit only solo in kit Part available Particolare disponibile in kit also anche in kit Part Number Description Codice...

Страница 19: ......

Страница 20: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Страница 21: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Отзывы: