Symptom: 

When using an external shunt the current reading is wrong 

Possible Causes:  

 

The external shunt has not been configured properly. Two values in the configuration page 

need to be changed: “Range” and “Current Shunt Resistance”. The range should be 
“Bidirectional”, and the value immediately higher than the rated shunt voltage drop. F

or 

example for a 75mV shunt, /- 80mV. The Shunt resistance has to be calculated based 
on the shunt used.  

 

Resistance(mOhm) = Voltage(mV) divided by current(A) 

 

The 500A shunts sold by Thornwave Labs are 0.15mOhms in value.  

 

 

Содержание BT-DCPM

Страница 1: ...1 PowerMon Bluetooth LE Advanced Battery Monitor DC Power Meter QUICKSTART GUIDE...

Страница 2: ...Required tools materials To complete the installation of the PowerMon device the following tools and materials are required wire cutters wire strippers small flat screwdriver long nose pliers externa...

Страница 3: ...erproof Warning The device is to be connected to DC circuits only not exceeding 75V and 60A using the integrated current shunt Failure to do so will result in equipment damage Higher currents are supp...

Страница 4: ...ent shunt connect this terminal to ES terminal 5 5 ES External shunt connection When using the internal current shunt connect this terminal to ES terminal 4 6 NC DO NOT CONNECT 7 V2 Second monitored v...

Страница 5: ...Connect up to 6 AWG wires to IS IS terminals 9 and 10 Please check the diagrams in the user manual For now it does not matter which wire goes where If IS IS are swapped the sign of the current readin...

Страница 6: ...t one side of the coil to RELAY terminal 3 and the other side to the load side of the shunt In this case the battery voltage cannot exceed 32V Check the user manual for more details Use 16 22AWG wire...

Страница 7: ...figure the device appropriately external shunt resistance value voltage drop range From the factory the device is already configured to use the integrated shunt Offset zero ing Because of the extremel...

Страница 8: ...tual current is zero disconnect the current wires if required and execute the Zero Current procedure again Symptom The PowerMon app is not finding any device Possible Causes The PowerMon device is not...

Страница 9: ...need to be changed Range and Current Shunt Resistance The range should be Bidirectional and the value immediately higher than the rated shunt voltage drop For example for a 75mV shunt choose 80mV The...

Отзывы: