SAFETY INSTRUCTIONS

 

 
Warning ! 

Read all the instructions and cautions before using the PowerMon device. Thornwave Labs Inc 

does not assume responsibility for any injury or property damage caused by improper installation, bad 
wiring  or  use  of  PowerMon  outside  of  its  intended  purpose.  The  device  should  be  installed  by  a 
professional. 

 

Warning ! 

The PowerMon device should not be used for any medical purposes, life sustaining equipment, 

safety applications or any application where equipment failure can cause injury, death, fires, or any other 
hazard. 

 

Warning ! 

There are no serviceable parts or fuses inside the power meter! Do not disassemble or attempt 

to repair! The unit operates with voltages up to 75V which can be lethal or cause serious and permanent 
injury. 

 
Warning ! 

Do not submerge under water or other liquids. The device is weatherproof but not waterproof. 

 
Warning ! 

The device is to be connected to DC circuits only, not exceeding 75V and 60A (using the integrated 

current shunt). Failure to do so will result in equipment damage. Higher currents are supported when 
using an external current shunt. Confirm that all connections are tight to avoid excessive heating and 
sparks. Never connect the V1 or V2 terminals to a power source without using a fuse or circuit breaker. 
A 0.1A to 2A fuse or circuit breaker is required. 

 
Warning ! 

Batteries are dangerous! Do not short-circuit a battery or the power meter. Batteries can produce 

flammable  and  explosive  gases  and  can  generate  extremely  high  currents  that  can  lead  to  serious 
consequences including explosion, fire, damage to equipment, personal injury and even death. It is the 

user’s responsibility to operate the equipment in a safe manner. Do not charge batteries in an enclosed 

environment  unless  allowed  by  the  manufacturer  of  the  battery.  Never  connect  a  load  to  a  battery 
without using fuses or circuit breakers properly sized for the wires/ equipment.  

 

 

 

Содержание BT-DCPM

Страница 1: ...1 PowerMon Bluetooth LE Advanced Battery Monitor DC Power Meter QUICKSTART GUIDE...

Страница 2: ...Required tools materials To complete the installation of the PowerMon device the following tools and materials are required wire cutters wire strippers small flat screwdriver long nose pliers externa...

Страница 3: ...erproof Warning The device is to be connected to DC circuits only not exceeding 75V and 60A using the integrated current shunt Failure to do so will result in equipment damage Higher currents are supp...

Страница 4: ...ent shunt connect this terminal to ES terminal 5 5 ES External shunt connection When using the internal current shunt connect this terminal to ES terminal 4 6 NC DO NOT CONNECT 7 V2 Second monitored v...

Страница 5: ...Connect up to 6 AWG wires to IS IS terminals 9 and 10 Please check the diagrams in the user manual For now it does not matter which wire goes where If IS IS are swapped the sign of the current readin...

Страница 6: ...t one side of the coil to RELAY terminal 3 and the other side to the load side of the shunt In this case the battery voltage cannot exceed 32V Check the user manual for more details Use 16 22AWG wire...

Страница 7: ...figure the device appropriately external shunt resistance value voltage drop range From the factory the device is already configured to use the integrated shunt Offset zero ing Because of the extremel...

Страница 8: ...tual current is zero disconnect the current wires if required and execute the Zero Current procedure again Symptom The PowerMon app is not finding any device Possible Causes The PowerMon device is not...

Страница 9: ...need to be changed Range and Current Shunt Resistance The range should be Bidirectional and the value immediately higher than the rated shunt voltage drop For example for a 75mV shunt choose 80mV The...

Отзывы: