background image

© 2018 Thorlabs

2 Getting Started

5

2

Getting Started

2.1

Parts List

Inspect the shipping container for damage.

If the shipping container seems to be damaged, keep it until you have inspected the contents
for completeness and tested the TSP01 mechanically and electrically.

Verify that you have received the following items within the package:

1. TSP01: Temperature and Humidity USB Sensor Probe
2. TSP-TH: External Temperature Probe for TSP01
3. USB Extension Cable, 1.8 m
4. Quick Reference

2.2

Requirements

The TSP01 is controlled and data read out is monitored through software on a connected PC. 

Users  have  the  choice  to  either  use  the  Thorlabs 

TSP01  Application

  software  as  a  separate

GUI or to run the TSP01 from other Thorlabs' software such as the 

Beam Profiler Software

.

Users are also free to write a separate application or use a third party GUI. For this, please see
the chapter 

Write-Your-Own-Application

The following are the requirements for the PC to be used for remote operation of the TSP01.

2.2.1 Hardware Requirements

.

CPU

1 GHz or higher

RAM

512 MB or more

Graphic Card

at least 32 MB memory

Graphic Resolution

min. 1024 x 768

Hard Disc

min. 100 MB of available disk space (32 bit)
min. 100 MB of available disk space (64 bit)

Interface

free USB 2.0 port, USB cable according the USB 2.0
specification

2.2.2 Software Requirements

The TSP01 software is compatible with the following operating systems:

·

Windows

®

 XP (32-bit) SP3

·

Windows

®

 Vista (32-bit, 64-bit)

·

Windows

®

 7 (32-bit, 64-bit)

·

Windows

®

 8.1 (32-bit, 64-bit)

·

Windows

®

 10 (32-bit, 64-bit)

 Note 

As  of  12/2018,  Thorlabs  introduces  the  TSP01  revision  B.  These  revised  TSP01  devices  are
labeled  "RevB"  on  the  underside  and  use  an  instrument  driver  that  no  longer  requires    NI-
VISA™. For operation of the previous version of the TSP01 without the RevB label, NI-VISA™
(version 5.1 or higher) is required for the driver.

19

Содержание TSP-TH

Страница 1: ...Environmental Measurement TSP01 Operation Manual 2018...

Страница 2: ...Version Date 1 4 21 Nov 2018 Copyright 2018 Thorlabs...

Страница 3: ...enus 15 3 2 7 Logging Panel 16 3 2 8 Save Data 16 3 2 9 Load Data 17 3 2 10 Export Settings 17 3 2 11 Import Settings 18 3 2 12 Device Information 4 Write Your Own Application 19 19 4 1 WYOA for TSP01...

Страница 4: ...31 7 1 Technical Data 32 7 2 List of Acronyms 33 7 3 Safety 34 7 4 Certifications and Compliances 35 7 5 Warranty 35 7 6 Copyright and Exclusion of Reliability 36 7 7 Thorlabs Worldwide Contacts...

Страница 5: ...ing forward to hearing from you Thorlabs GmbH Warning Sections marked by this symbol explain dangers that might result in personal injury or death Always read the associated information carefully befo...

Страница 6: ...p plication software allows to enter individual NTC parameters such as R0 reference resist ance T0 reference temperature and the B coefficient The TSP01 can be run and data can be displayed in the Tho...

Страница 7: ...or use a third party GUI For this please see the chapter Write Your Own Application The following are the requirements for the PC to be used for remote operation of the TSP01 2 2 1 Hardware Requiremen...

Страница 8: ...ion Please make sure that the in stallation is carried out completely including the reboot requests Save the ZIP file to your computer and unpack the archive Double click the setup exe to install Shie...

Страница 9: ...ed information on how to use the TSP01 Application software please see the chapter Detailed GUI Description 3 1 Quick Start This chapter gives a short overview on how to use the TSP01 Application A de...

Страница 10: ...nt Interval Set the logging interval time between two measurements between 1 and 10000 seconds Averaging Averaging unchecked A single measured value per selected measurement interval will be logged Av...

Страница 11: ...enabled or not present the values show Remarks This column is empty if no error oc curred Otherwise an error message will be dis played Tab Graph If enabled in the Settings menu the tab Graph will di...

Страница 12: ...panel you can adjust the appearance of the GUI change thermistor settings and en able disable a sensor Tool tips appear when moving the mouse pointer over the appropriate parameter Detailed explanati...

Страница 13: ...n the Function column Menu Menu Topic Icon Function Load Data Load measurement data from a file Save Data Save measurement data to a file Import Settings Import configuration file Export Setting Expor...

Страница 14: ...alue of the reference sensor by adding a positive or negative offset This individual offset is displayed for each af fected sensor Unchecking this box returns all sensors to display of the actually me...

Страница 15: ...color changes depending on the value The thresholds for color change as well as upper and lower limit of the bar can be adjusted in the Settings panel 3 2 4 Tab Table In the tab Table the logging resu...

Страница 16: ...ite color Drag a rect angle over the area to be zoomed and release the mouse button In order to return to the full graphical display auto scaling click to the Zoom Home button The time axis shows time...

Страница 17: ...le value will be logged only Logging Control Three modes can be set manual start stop timed logging or logging of a number of samples Time Axis Scale Three selections are available time in seconds tim...

Страница 18: ...file includes a header with sensor and software in formation application settings and the logged measurement data 3 2 9 Load Data Saved data can be loaded into the GUI Click to the icon or select fro...

Страница 19: ...enu File the Export Settings item A dialog opens Type in a file name and click Save The file includes the sensor and software information and the application settings 3 2 11 Import Settings Saved sett...

Страница 20: ...2018 Thorlabs 18 TSP01 3 2 12 Device Information The Device Information menu retrieves information on the connected TSP01...

Страница 21: ...cations As for this reason in 32 bit systems they are installed to C Program Files while in 64 bit systems to C Program Files x86 In the table below you will find a summary of the files needed for spe...

Страница 22: ...Foundation VISA WinNT TLTSPB TLTSPB fp Online Help for Instrument driver C Program Files IVI Foundation VISA WinNT TLTSPB Manual NI LabVIEW driver C Program Files National Instruments LabVIEW xxxx In...

Страница 23: ...NI VISA engine can be installed from the following sources The software CD shipped with previous revision TSP01 sensors not labeled RevB The in staller includes NI VISA The National Instruments websit...

Страница 24: ...t require NI VISA In order to write your own application for TSP01 you need a specific instrument driver and some tools for use in different programming environments The driver and tools are being in...

Страница 25: ...TLTSP_32 dll C Program Files IVI Foundation VISA WinNT Bin TLTSP_64 dll Note This instrument driver is required for all development environments Source file C Program Files IVI Foundation VISA WinNT...

Страница 26: ...e for C Solution file C Program Files IVI Foundation visa WinNT TLTSP01 Examples MS_VISUALCPP TSP01_CPP_Sample sln Project file C Program Files IVI Foundation visa WinNT TLTSP01 Examples MS_VISUALCPP...

Страница 27: ...enable command Sets the Standard Event Enable Register ESE Event enable query Returns the Standard Event Enable Register ESR Event status register query Returns and clear the Standard Event Register...

Страница 28: ...mmands 5 TST self test query run self test and read result Use this query command to perform the instrument self test routine The command places the coded result in the Output Queue A returned value o...

Страница 29: ...alue Set Steinhart Hart parameter C C MIN MAX DEF Query Steinhart Hart parameter C EXPonential R0 MIN MAX DEF value Set parameter R0 for exponential RT calc R0 MIN MAX DEF Query parameter R0 for expon...

Страница 30: ...1 Configure device for temperature measurement on internal sensor HUMidity Configure device for humidity measurement TEMPerature2 Configure device for temperature measurement on external thermistor s...

Страница 31: ...TSP01 please read the section Safety and contact Thorlabs tech support and an engineer will be happy to assist you Attention To avoid damage to the instrument do not expose it to spray liquids or solv...

Страница 32: ...is not labeled RevB in which case it will require installation of the NI VISA software Please down load NI VISA or in case you used your own application please adjust the driver Altern atively instal...

Страница 33: ...ge 15 C to 200 C Accuracy 0 5 C 25 C Resolution 0 05 C External Sensors Number of channels 2 Connector 2 5 mm earphone jack Supported Sensor Type NTC Units C K F Measurement Range 200 W to 80 kW Inter...

Страница 34: ...ollowing acronyms and abbreviations are used in this manual GUI Graphic User Interface NTC Resistor with Negative Temperature Coefficient aka Thermistor RH Relative Humidity SCPI Standard Commands for...

Страница 35: ...cause harmful interference to radio communications However there is no guarantee that interfer ence will not occur in a particular installation If this equipment does cause harmful interference to ra...

Страница 36: ...2018 Thorlabs 34 TSP01 7 4 Certifications and Compliances...

Страница 37: ...r the technical data of the de scribed unit at any time 7 6 Copyright and Exclusion of Reliability Thorlabs has taken every possible care in preparing this document We however assume no li ability for...

Страница 38: ...l 55 16 3413 7062 Fax 55 16 3413 7064 www thorlabs com Email brasil thorlabs com Japan Thorlabs Japan Inc 3 6 3 Kitamachi Nerima ku Tokyo 179 0081 Japan Tel 81 3 6915 7701 Fax 81 3 6915 7716 www thorl...

Страница 39: ...www thorlabs com...

Отзывы: