: Please plug the SFP’s into the free cage positions. Keep in mind
your desired configuration when equipping the SFP’s.
9.
Set the DIP switches to the positions which correspond to your desired application.
Information for the DIP switch set-up can be found under
Operating Mode Selection
10.
Attach the connection cables (CATx- cable) between the THOR Small Switch and Local
Unit and between the THOR Small Switch and Remote Unit. Use the provided crossover
CATx- cable or insert the provided crossover cable with the provided CATx- coupler
before/after your CATx- wiring.
11.
Depending upon your application, it may be necessary to make a connection to a
controller over the serial interface. Attach the provided RJ45 to DSUB 9-pin cable at the
socket of the serial interface and connect it with your controller. More information for
control through the serial interface can be found on pages
81
,
88, and 98.