background image

THOR-SSM 

Rev. : 02/09/2012

Welcome to the THOR Family! 

Thank you for purchasing a THOR Small Switch! We appreciate your business, and we think 
you’ll appreciate the many ways that your THOR system will save you money, time, and 
effort. 

The THOR Small Switch offers three fundamental uses: 

As a Multiplex Repeater: the DVI signals (+optional audio) coming from a signal
source are equalized and distributed on up to 7 equivalent outputs. A control is not
necessary. Distributed display systems can be realized (Digital Signage).

As an 8-port Crosspoint Switch: each port can be switched optionally as an input or
output. You can, for example, switch and distribute the signals from 3 signal
sources on up to 5 displays (allowing simultaneous presentations on several
displays). Alternatively, signals coming from 7 signal sources can be switched in
turn to a single display. The changeover can be triggered remotely using the serial
interface (RS232) and/or by a push-button at the device.

As a 7-port KVM Switch: up to 7 Single-head ports (a “Single-head” extender
system supports 1x monitor, 1x keyboard, 1x mouse) or up to 3 Dual-head ports (a
Dual-head extender system supports 2x monitor, 1x keyboard, 1x mouse). The
changeover can be triggered remotely using the serial interface (RS232) and/or by a
push-button at the device.

Cascade multiple devices in two stages for all applications to give up to 49/1 connections. 

The THOR Small Switch has the advantage that it can be positioned up to 140m away from 
both your signal source and display device. This becomes possible by using the proven 
THOR Extender technology for the transmission of DVI- Monitor and USB-Keyboard and 
Mouse signals over CATx- cable.  

The operation of a THOR Small Switch always requires at least one Local Unit and up to 
seven Remote Units from the THOR Extenders range.  

DISCONTINUED

Содержание TH-SSM

Страница 1: ...n be switched in turn to a single display The changeover can be triggered remotely using the serial interface RS232 and or by a push button at the device As a 7 port KVM Switch up to 7 Single head por...

Страница 2: ...R SSM SWITCH SMALL FIBER NO GBIC TH SU THOR SU SWITCHING UNIT THOR KVM DVI extending devices TH E KIT 1 SL 4 CAT THOR E EXTENDER KIT 1Mon SL 4xHID CATx TH E KIT 1 SL 4 CAT A232 THOR E EXTENDER KIT 1Mo...

Страница 3: ...TENDER KIT 2Mon SL 4xHID CATx Anal Audio RS232 TH E KIT 2 SL 4 CAT DA THOR E EXTENDER KIT 2Mon SL 4xHID CATx Dig Audio TH E KIT 2 SL 4 MM THOR E EXTENDER KIT 2Mon SL 4xHID MM Fiber TH E KIT 2 SL 4 MM...

Страница 4: ...2 CATx TH E KIT 4 SL 24 CAT A232 THOR E EXTENDER KIT 4Mon SL 2xHID 4xUSB2 CATx Anal Audio RS232 TH E KIT 4 SL 24 CAT DA THOR E EXTENDER KIT 4Mon SL 2xHID 4xUSB2 CATx Dig Audio TH E KIT 4 SL 24 MM THOR...

Страница 5: ...he manufacturer assume any liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change the specifications functions or circuitry of t...

Страница 6: ...roperties The safety documentation noted in this manual shall be considered in detail The length of the attached CPU or Console Cables must not exceed 3m The use of suggested interconnect cables is ma...

Страница 7: ...space without any airflow Do not place a power supply directly on top of a unit Do not obscure a unit s ventilation holes To safeguard against personal injury and avoid possible damage to equipment o...

Страница 8: ...THOR SSM 8 Rev 02 09 2012...

Страница 9: ...1 THOR Small Switch for CATx 34 Configuration Multiplex Repeater 1 Source up to 7 Displays 34 Configuration Multiplex Repeater 2 Sources each up to 3 Displays 34 Configuration Multiplex Repeater 4 Sou...

Страница 10: ...mple Applications 68 Indicator LEDs 70 Meaning of the diagnostic LEDs 70 Setup 71 Operation 71 By serial interface 71 Control commands 71 7 2 Crosspoint Switch 72 Configuration Crosspoint Switch 1 Inp...

Страница 11: ...ce 97 Control commands 98 Examples 98 c By the attached keyboard 99 User commands 99 Call of the command mode till firmware dated Nov 20 2009 100 Change of the initialization string till Nov 20 2009 1...

Страница 12: ...pport 134 Appendix G List of supported USB devices 135 Appendix H Specifications 136 A THOR Media KVM Local Remote Unit 136 Power Supply 136 Interface depending on type of device 136 Audio Interface 1...

Страница 13: ...12 13 Power Supply 144 B THOR Small Switch Unit 145 Serial Interface 145 C All THOR Devices 146 Power Supply 146 CATx Interfaces 146 Appendix J Connection Cable 147 Serial cable to connect the THOR Sm...

Страница 14: ...e THOR Small Switch with the help of the provided stickers according to your application 2 Set the DIP switch according to your application 3 Connect THOR Small Switch to Local unit with CATx cable s...

Страница 15: ...lays Alternatively signals coming from 7 signal sources can be switched in turn to a display The changeover can be triggered remotely using the serial interface RS232 and or by a push button at the de...

Страница 16: ...Multimode fiber cable Singlemode 9 Singlemode fiber cable KVM Keyboard Video and Mouse Console Keyboard Mouse and Monitor Dual Access A system allowing connection of Local and Remote User Consoles Sin...

Страница 17: ...stem Example application for a THOR Small Switch System Multiplex Repeater or Crosspoint Switch Up to 7 remote monitors and audio outputs CPU with DVI graphic card and audio output THOR Extender Local...

Страница 18: ...simultaneously keyboard and mouse or keyboard and touch screen etc but not e g keyboard mouse and touch screen simultaneously You can extend a USB hub but this does not raise the number of supported...

Страница 19: ...n SL 4xHID CATx Dig Audio TH E KIT 1 SL 2 CAT THOR E EXTENDER KIT 1Mon SL 2xHID CATx TH E KIT 1 SL 2 CAT A232 THOR E EXTENDER KIT 1Mon SL 2xHID CATx Anal Audio R S232 TH E KIT 1 SL 2 CAT DA THOR E EXT...

Страница 20: ...THOR E EXTENDER KIT 1Mon SL 4xHID MM Fiber Dig Audio TH E KIT 1 SL 2 MM THOR E EXTENDER KIT 1Mon SL 2xHID MM Fiber TH E KIT 1 SL 2 MM A232 THOR E EXTENDER KIT 1Mon SL 2xHID MM Fiber Anal Audi o RS232...

Страница 21: ...M Fiber TH E KIT 1 SL 2 SM A232 THOR E EXTENDER KIT 1Mon SL 2xHID SM Fiber Anal Audi o RS232 TH E KIT 1 SL 2 SM DA THOR E EXTENDER KIT 1Mon SL 2xHID SM Fiber Dig Audio TH E KIT 1 SL 2 SM V THOR E EXTE...

Страница 22: ...KIT 4 SL 8 SM DA THOR E EXTENDER KIT 4Mon SL 8xHID SM Fiber Dig Audio TH E KIT 4 SL 24 SM THOR E EXTENDER KIT 4Mon SL 2xHID 4xUSB2 SM Fiber TH E KIT 4 SL 24 SM A232 THOR E EXTENDER KIT 4Mon SL 2xHID 4...

Страница 23: ...LY use with other HID devices Human Interface Device such as touch screens graphics tablets barcode readers or similar may be successful but there is no guarantee for this The THOR KVM is NOT suitable...

Страница 24: ...screen and stored in the internal DDC table To modify the DDC Setup see DDC color depth page 62 Selecting the moment of switching to the next frame The transmission of screen data in not synchronous t...

Страница 25: ...l Switch for CATx package THOR Small Switch 1x 5V DC universal power supply for the THOR Small Switch 1x serial cable RJ45 DB9 Female for switching purpose 1x power cord 1x sheet of product stickers U...

Страница 26: ...udio Serial cable 1 8m Serial DB9 male female 2 audio cables 1 8m Additionally with THOR KVM Dual Head and Media devices with Audio 1x Serial link audio ZIP type cable 1 8m with one side DSUB9pin fema...

Страница 27: ...d be in your THOR KVM Media Remote Unit package THOR KVM Media Remote Unit 1x 5V DC universal power supply for the THOR KVM Media Remote Unit 1x power cord If anything is missing please contact Techni...

Страница 28: ...ensure that the connection is tension free Serial cable Connect the supplied serial cable to your CPU signal source Audio cable Connect the supplied audio cable to your CPU CATx cable Recommended cabl...

Страница 29: ...anels in the line is possible and allowed Not allowed is a connection from the Fiber link interface LC to any other products especially telecommunications or network equipment Our experiences show tha...

Страница 30: ...Connect the CPU signal source to the Local Unit using the supplied cable s 4 Connect the devices with INTERCONNECT cables fiber or CATx 5 Take the THOR Small Switch out of the packaging and also the...

Страница 31: ...able between the THOR Small Switch and Local Unit and between the THOR Small Switch and Remote Unit Use the provided crossover CATx cable or insert the provided crossover cable with the provided CATx...

Страница 32: ...r approved replacement 13 For a dual access system connect the monitor for the local console to the appropriate port on the Local Unit The port may also be used to feed into a KVM switch To attach a l...

Страница 33: ...ting parts In 19 rack cabinets the area to the right and left from the THOR Small Switch must be kept free The THOR Small Switch its extenders and power supplies may become warm Do not install the uni...

Страница 34: ...tiplex Repeater Connect to the THOR Media Remote Units Push button no function in this operating mode Push button no function in this operating mode R L R R R R R R Connect to the THOR Media Local Uni...

Страница 35: ...Crosspoint Switch 1x7 Connect to 5V power supply Push button no function in this operating mode LA LB LD LC RA RB RD RC Connect to the THOR KVM Media Local Units Connect to the THOR KVM Media Remote U...

Страница 36: ...h 3x5 R5 R3 R4 R2 R1 R6 L1 L2 Push button for the sequential selection of pre programmed configurations Connect to 5V power supply Connect to the THOR Media Local Units Connect to the THOR Media Remot...

Страница 37: ...ch 5x3 Pushbutton for the sequential selection of pre programmed configurations Connect to 5V power supply L4 L1 L2 L3 R2 R4 R3 R1 Pushbutton for the sequential selection of pre programmed configurati...

Страница 38: ...h 1x7 Connect to 5V power supply L4 L1 L2 L3 R2 R1 L5 L6 Pushbutton for the sequential selection of pre programmed configurations Connect to 5V power supply Connect to the THOR Media Local Units Conne...

Страница 39: ...nits CPU Video 1 K M Connect to the THOR KVM Remote Units Console Video 1 K M L4 L1 L2 L3 R L5 L6 L7 Connect to 5V power supply Connect to the THOR KVM Local Units CPU Push button for the sequential s...

Страница 40: ...THOR SSM 40 Rev 02 09 2012 THOR Small Switch rear view Serial Interface RS232 Operating Mode DIP switch...

Страница 41: ...4 2 THOR Media Extender THOR Media Local Unit THOR Media Remote Unit THOR Media Audio Local Unit To CPU DVI Connect to remote DVI monitor Connect to local DVI monitor To CPU DVI Connect to local DVI m...

Страница 42: ...nit rear view Audio Out Connect to 5V power supply Remote DVI monitor port connect to remote console monitor Serial Out INTERCONNECT carries video and data signals connect to Local Remote Unit with CA...

Страница 43: ...43 4 3 THOR KVM Extender THOR KVM Local Unit THOR KVM Remote Unit Remote keyboard mouse port To CPU DVI graphic card Connect to local DVI monitor Remote DVI monitor port Connect to remote console mon...

Страница 44: ...R KVM Local Remote Unit rear view Connect to 5V power supply INTERCONNECT carries video and data signals connect to Local Remote Unit with CATx cable Connect to 5V power supply INTERCONNECT carries vi...

Страница 45: ...al Unit with audio THOR KVM Remote Unit with Audio Audio In To CPU Serial To CPU DVI Connect to CPU USB Audio Out Serial Out Connect to local DVI monitor Remote DVI monitor port Connect to remote cons...

Страница 46: ...4x USB HID To CPU DVI Connect to CPU USB Program Connect to local DVI monitor Remote DVI monitor port Connect to remote console monitor Remote keyboard mouse port Connect to CPU secondary USB Remote...

Страница 47: ...THOR SSM Rev 02 09 2012 47 THOR KVM Local Unit with DVI I Input DVI D VGA Connect to CPU USB Connect to local DVI monitor...

Страница 48: ...R KVM Local Remote Unit with audio rear view Connect to 5V power supply INTERCONNECT carries video and data signals Connect to Local Remote Unit with CATx cable Connect to 5V power supply INTERCONNECT...

Страница 49: ...graphic card 2nd local DVI monitor port Connect to local console 2nd monitor Connect to CPU 1st DVI graphic card Local DVI monitor port Connect to local console monitor 2nd remote DVI monitor port Co...

Страница 50: ...2nd local DVI monitor port Connect to local console 2nd monitor Connect to CPU 1st DVI graphic card Local DVI monitor port Connect to local console monitor 2nd remote DVI monitor port Connect to remot...

Страница 51: ...itor port Connect to remote console 2nd monitor 1st remote DVI monitor port Connect to remote console 1st monitor 2nd local DVI monitor port Connect to local console 2nd monitor Connect to CPU DVI cab...

Страница 52: ...x USB 2 0 THOR KVM Remote Unit with 2x USB HID 4x USB 2 0 To CPU DVI Connect to CPU USB Connect to local DVI monitor Remote DVI monitor port Connect to remote console monitor Remote keyboard mouse por...

Страница 53: ...wer supply INTERCONNECT carries 2nd video Connect to Local Remote Unit with CATx cable INTERCONNECT carries 1st video and data signals Connect to Local Remote Unit with CATx cable INTERCONNECT carries...

Страница 54: ...n below Diagnostic LEDs at THOR Small Switch for CATx LED Appearance Diagnostics Power LED Red LED Off On Device not ready Device ready Link Status Orange LED Off Orange On Orange Blinking Green On Gr...

Страница 55: ...all Switch for Fiber LED Appearance Diagnostics Power LED Red LED Off On Device not ready Device ready Link Status Orange LED Off Orange On Orange Blinking Green On Green Blinking No transmission over...

Страница 56: ...Appearance Diagnostics Power LED Red LED Off On Device not ready Device ready Video Okay Green LED Off On No or invalid video signal detected Device ready Link Status Green LED blinking On No CATx con...

Страница 57: ...ts and outputs may be changed In doing so it is possible to interconnect two transmitters this may damage the connected equipment The location of the operating mode selector DIP switch is shown below...

Страница 58: ...point Switch Every port can either be an input to a Local Unit or an output to a Remote Unit Each connection input output is possible 1x IN 7x OUT The signals of one source can be switched to up to 7...

Страница 59: ...ower off 2 set the DIP switch 3 switch power on the device is resetting 4 switch power off 5 set the DIP switch back 6 switch power on done Operating Mode after Reset Power ON After reset the respecti...

Страница 60: ...allows programming and processing the switching functions of the THOR via Infrared Remote Control Additionally this device has 8 digital inputs to recall macro functions CP mode or for direct switchin...

Страница 61: ...nscrew the Philips screws at the bottom of the device Carefully remove the lower and upper shells of the case The jumper is located as shown in the following figure Plug the jumper on the two pins The...

Страница 62: ...s at the bottom of the device Unscrew the UNC type screws on each side of the monitor connectors Carefully displace the lower and upper shells of the case The following diagnostic LEDs are used to ind...

Страница 63: ...agram to locate jumpers DDC color depth You can select whether the DDC information is taken from internal DDC table from the local monitor or downloaded from the remote monitor and stored in internal...

Страница 64: ...o the Local Unit and stored into the DDC EPROM After a successful programming of the DDC EPROM the Video OK LED at the Local Unit will blink rapidly for approx 1 second Done Selection of Color depth Y...

Страница 65: ...ssion is terminated when a frame is displayed on the screen If the device switches to the new frame during HSYNC the displaying period of the old frame you may see horizontal screen breaks at the mome...

Страница 66: ...to the second stage repeaters allowing up to 49 display units to be controlled The distance between a Local Unit and THOR Small Switch or between a THOR Small Switch and Remote Unit or between two TH...

Страница 67: ...four Local Units are transferred over CATx cables to one equivalent Remote Unit This allows an extension of the cable length if the usual 140m distance by CATx cables is not sufficient Connect to 5V p...

Страница 68: ...SSM 68 Rev 02 09 2012 Example Applications A video audio source is switched over the THOR Small Switch to 4 different screens loudspeakers Additionally a control monitor can be attached at the Local...

Страница 69: ...THOR SSM Rev 02 09 2012 69 Three cascaded THOR Small Switches each with a local second screen and 13 screens for presentations...

Страница 70: ...pearance Diagnostics Power LED Red LED Off On Device not ready Device ready Link Status Orange LED Off Orange On No transmission over the CATx cable attached local remote unit is disconnected switched...

Страница 71: ...to the CPU is included in delivery For the complete communication protocol and an explanation of the control characters please see Appendix E Protocol for command mode For communication please set up...

Страница 72: ...rom the THOR Small Switch the transmission continues over CATx cables to up to 7 Remote Units Alternatively a further THOR Small Switch slave can be used between the first stage switch and further Rem...

Страница 73: ...ched on up to 6 outputs and transferred over CATx cables to 6 Remote Units Optionally an additional THOR Small Switch can be inserted for a second switching stage R1 R3 R2 R4 R5 R6 R7 L Connect to the...

Страница 74: ...ched on up to 4 outputs and transferred over CATx cables to 4 Remote Units Optionally an additional THOR Small Switch can be inserted for a second switching stage L1 L2 L3 R2 R4 R5 R3 R1 Connect to th...

Страница 75: ...witched on up to 2 outputs also on several and be transferred over CATx cables on up to 2 Remote Units Optionally an additional THOR Small Switch can be inserted for a second switching stage Push butt...

Страница 76: ...be transferred over CATx cables to one Remote Unit Optionally an additional THOR Small Switch can be inserted for a second switching stage Connect to 5V power supply L4 L1 L2 L3 L5 L6 L7 Connect to th...

Страница 77: ...THOR SSM Rev 02 09 2012 77 Example Application Three video sources are switched over the THOR Small Switch on four different screens...

Страница 78: ...t the respective DEFAULT Mode is selected 1x7 Input I1 is switched to Output O1 2x6 I1 to O1 and I2 to O2 3x5 I1 to O1 I2 to O2 and I3 to O3 4x4 I1 to O1 I2 to O2 I3 to O3 and I4 to O4 5x3 I1 to O1 I2...

Страница 79: ...Power LED Red LED Off On Device not ready Device ready Link Status Orange LED Off Orange On Green blinking No transmission over the CATx cable attached local remote unit is disconnected switched off...

Страница 80: ...uration is loaded The macro will only be executed if the push button is not operated for longer than 2 seconds If the push button is released for longer than 2 seconds the operation is cancelled The s...

Страница 81: ...amples STX 0x54 ETX Reset the switch and set the connections as a function of SW7 see above STX 0x40 0x80 ETX Read the system info version number from the switch STX 0x52 ETX Switch off all local remo...

Страница 82: ...THOR SSM 82 Rev 02 09 2012 c By the attached keyboard Since Firmware Revision dated Nov 20 2009 you can also switch the Console 1 which is connected to Remote Unit 1 using the attached keyboard...

Страница 83: ...serial interface Cascading of the THOR KVM Switch in two stages allows up to 49 CPUs to be addressed In addition to the DVI signals and USB for keyboard mouse bi directional stereo audio serial RS232...

Страница 84: ...THOR SSM 84 Rev 02 09 2012 Example Application Four CPUs are switched over the THOR Small Switch to one console...

Страница 85: ...m or if THOR KVM Switches are cascaded it is on the highest level directly after the console The device is Slave if THOR KVM Switches are cascaded it is on second level directly after the Local Units...

Страница 86: ...nge On Orange Blinking Green On Green blinking No transmission over the CATx cable attached local remote unit is disconnected switched off or a broken interconnect cable Connection through CATx cable...

Страница 87: ...y a rapidly blinking LED If the last channel is reached the device will cycle to the first channel b By serial interface You can find the allocation of the serial interface under Serial Interface on p...

Страница 88: ...the existing connection is disconnected at the same time where Loc No 7Bit date 1 to 7 Examples STX 0x54 ETX Reset the switch and set the connections as a function of SW7 see above STX 0x40 0x80 ETX...

Страница 89: ...e command mode User commands The input of upper lower case letters does not matter Key1 Key2 means that all keys must be pressed at the same time Key1 Key2 means that the keys must be pressed successi...

Страница 90: ...left ALT press twice rapidly 6 right ALT right ALT press twice rapidly 7 left CTRL right CTRL simultaneous 8 left CTRL SHIFT right CTRL SHIFT simultaneous 9 left CTRL ALT right CTRL simultaneous Call...

Страница 91: ...x number of the port Caution Applies only to the selected level M x S y RETURN or M 0 x S 0 y RETURN Only in cascaded applications Switch the master to port 0x and the attached slave on port 0y with x...

Страница 92: ...digits 1 to 7 y ASCII digits 1 to 7 Examples CTRL SHIFT I Call the command mode SHIFT 3 Switch immediately to port 3 after call the master is selected M2S5 RETURN Switch the master to port 2 and the s...

Страница 93: ...two stages for all applications allowing up to 9 dual head CPUs to be addressed In addition to the DVI signals and USB for keyboard mouse bi directional stereo audio serial RS232 V24 data can be trans...

Страница 94: ...THOR SSM 94 Rev 02 09 2012 Example Application Three CPUs with dual head graphic cards and local consoles switched over the THOR Small Switch to one console...

Страница 95: ...stem or if THOR KVM Switches are cascaded it is on highest level directly after the console The device is slave if THOR KVM Switches are cascaded it is on second level directly after the Local Units O...

Страница 96: ...Orange On Orange Blinking Green On Green blinking No transmission over the CATx cable attached local remote unit is disconnected switched off or a broken interconnect cable Connection through CATx cab...

Страница 97: ...rapidly blinking LED If the last channel is reached the device will switch to the first channel b By serial interface You can find the allocation of the serial interface under Serial Interface on pag...

Страница 98: ...Bit date 1 to 7 Examples STX 0x54 ETX Reset the switch and set the connections as a function of SW7 see above STX 0x40 0x80 ETX Read the system info version number from the switch STX 0x4F 0x81 0x81 E...

Страница 99: ...er commands The input of upper and lower case letters does not make a difference Key1 Key2 means that all keys must be pressed at the same time Key1 Key2 means that the keys must be pressed successive...

Страница 100: ...eft ALT press twice rapidly 6 right ALT right ALT press twice rapidly 7 left CTRL right CTRL simultaneous 8 left CTRL SHIFT right CTRL SHIFT simultaneous 9 left CTRL ALT right CTRL simultaneous Call o...

Страница 101: ...x number of the port Caution Applies only to the selected level M x S y RETURN or M 0 x S 0 y RETURN Only in cascaded applications Switch the master to port 0x and the attached slave on Port 0y with x...

Страница 102: ...ts 1 to 3 y ASCII digits 1 to 3 Examples CTRL SHIFT I Call the command mode SHIFT 3 Switch immediately to port 3 after call the master is selected M2S1 RETURN Switch the master to port 2 and the slave...

Страница 103: ...he complete communication protocol and an explanation of the control characters please see Appendix E Protocol for command mode For communication please set up the format of the serial data communicat...

Страница 104: ...he device In the Crosspoint Switch operating mode all macros in memory are reset Standard operating mode Reset the THOR Small Switch to default settings Factory Reset 1 switch power off 2 set the DIP...

Страница 105: ...ond reduces the capability of the data link Therefore the data has to be reduced before transmitting This is done by a so called RLE Run Length Encoding algorithm If this loss less compression does no...

Страница 106: ...output appears 50 70 ms Transmission of the graphic data into the extender system and transmission to the Remote Unit 15 45 ms Processing time in the graphical output device 15 100 ms where 15 ms are...

Страница 107: ...approx 34 ms 20fps USB HID devices Your USB HID device does not work Although our interface supports HID devices we can t ensure that every connected device will operate successfully If you have any...

Страница 108: ...THOR SSM 108 Rev 02 09 2012 Appendix A Example Applications This section illustrates some specific applications using the THOR THOR as Multiplex Repeater with audio option...

Страница 109: ...APPENDIX A EXAMPLE APPLICATIONS Rev 02 09 2012 109 Three cascaded THOR as Multiplex Repeater and a total of 13 screens for presentations...

Страница 110: ...THOR SSM 110 Rev 02 09 2012 THOR as Crosspoint Switch here 3x Input 4x Output...

Страница 111: ...APPENDIX A EXAMPLE APPLICATIONS Rev 02 09 2012 111 THOR as Single head KVM Switch to 7 1 optional with a local console and or serial audio option...

Страница 112: ...THOR SSM 112 Rev 02 09 2012 THOR as Dual head KVM Switch to 3 1 with a local console...

Страница 113: ...d plates in the list of parts delivered allow covering unused device positions Rack mount kit TH ACCS 130 List of parts delivered Mounting instruction Align the holes on the base plate with the vacant...

Страница 114: ...tion you can mount a rack mountable p s u type TH ACCS 132 instead of a regular device This p s u is capable of powering up to three devices Please note Use the rear mounting holes to fix the p s u Af...

Страница 115: ...list of parts delivered allow covering unused device positions Rack mount kit TH ACCS 131 List of parts delivered Mounting instruction Align the holes on the base plate with the vacant screw holes on...

Страница 116: ...H ACCS 131 allows mounting of up to 4 devices In the left hand position you can mount a rack mountable p s u type TH ACCS 132 instead of a regular device This p s u is capable of powering up to three...

Страница 117: ...38 4 KHz Signal Levels Line Level 5 Volts Pk Pk maximum Input Impedance 47K Local Unit Connectors 2 x 3 5mm stereo jack socket Line In Line Out Remote Unit Connectors 2 x 3 5mm stereo jack socket Lin...

Страница 118: ...usly No setup is required unless a microphone is connected to the Remote Unit Connect up as follows Take the line level output from your sound card green connector and connect to Line In on the extend...

Страница 119: ...remote control button sequences used in system configuration and video tuning on the local unit Infrared Remote Control IR RC Exit OSD Select next position increase parameter Select previous position...

Страница 120: ...You can adjust the following properties using the IR Remote Control Brightness contrast Selection of Input Signal You can adjust the following properties using the OSD Auto Configuration ON OFF Color...

Страница 121: ...trast adjust more brightness more contrast less brightness less contrast Reset to factory defaults Reset to factory defaults from flash resetting user presets press twice To navigate within the OSD ex...

Страница 122: ...ze and position Tools Set OSD position and size factory reset 4 Use the left and right arrow to highlight the icon you want The OSD displays additional icons relating to commands in the selected menu...

Страница 123: ...submenu 12 Press the Esc key to close the OSD saving all settings and restore normal mouse and keyboard functions The following table summarizes the keyboard actions and icons used to navigate the OSD...

Страница 124: ...lect menu Brightness Contrast Use this menu to adjust the brightness and contrast of the video image or to adjust the black level of a display Brightness Contrast menu Select VGA source Select DVI sou...

Страница 125: ...tion to a 4 3 resolution will result in an incorrect aspect ratio of the displayed picture If your input signals are DVI D and you use scaling for downsizing your picture there are limits for the scal...

Страница 126: ...to set up the color profile in RGB color space or by using one of five predefined color temperatures To view this menu select the Colors icon from the main menu and then select the Color Temperature...

Страница 127: ...lution is changed by an imposed fixed resolution sharpness can be affected Use this option to switch between three settings for optimum sharpness Automatic detection of the number of pixels per line a...

Страница 128: ...ut the procedure introduces a delay in the picture appearing on the attached console screen If you want the picture to appear as fast as possible you may want to disable this feature Auto Configuratio...

Страница 129: ...ion menu select the DDC icon from the main menu button DDC Configuration menu c Setup Instructions for RGB Input This procedure is designed to correct for discrepancies in the video signal due to anal...

Страница 130: ...clock value until all stripes have disappeared 8 3 Confirm the setting 20 Problems with the pixel phase will cause horizontal noise horizontal wave formed lines flicker or smearing with zebra pattern...

Страница 131: ...l elements Parameter description Command byte in the range of 0x40 0x6F see the list of allowed commands below Data Bytes a Binary data in order to prevent control commands being sent during the trans...

Страница 132: ...commands a Errors occurred NAK b No errors ACK c Optional reply command with data a repeat command b next command c receive and process the replay command Commands global functions Function Command A...

Страница 133: ...T to an INPUT STX 0x47 OUTPUT No INPUT No ETX ACK 2 switch off a single OUTPUT STX 0x48 OUTPUT No ETX ACK 3 switch a single OUTPUT feedback channel to INPUT STX 0x4B INPUT No OUTPUT No ETX ACK 4 switc...

Страница 134: ...hat type of keyboard brand of mouse make and model of monitor type and make of cable etc Any scenario that appears to create the problem or make it worse The results of any testing you ve already done...

Страница 135: ...set parameters Such devices are NOT supported by our extenders Please note installing more than two devices is not possible even if you use a USB hub The following devices are tested and have been fou...

Страница 136: ...ion Wiring acc EIA TIA 568B Gigabit Ethernet LC fiber 1000 Mbit High speed transmission Gigabit Ethernet Audio Interface Description Bi directional stereo audio link Transmission Method Digitized virt...

Страница 137: ...4 solid cable 140m 400ft CATx patch cable AWG26 8 stranded cable 70m 200ft Type of Interconnection Cable CATx installation cable AWG24 solid cable S UTP Cat5 cable acc EIA TIA 56A TSB 36 or Digital ST...

Страница 138: ...210x140x165mm 8 3 x5 5 x6 5 Weight 1 6 kg 3 5lb THOR KVM Dual head or THOR Media w Audio serial 103 x 143 x 42mm 4 x5 6 x1 1 2 devices Weight Local Remote 0 6kg 1 3lb each Shipping box 260x210x150mm...

Страница 139: ...th of Interconnection Cable CATx installation cable 140m 400ft AWG24 solid cable CATx patch cable 70m 200ft AWG26 8 stranded cable Type of Interconnection Cable CATx installation cable AWG24 solid cab...

Страница 140: ...ll Switch 103 x 143 x 42mm 4 x5 6 x1 1 Weight 0 6kg 1 3lb Shipping box 260x210x150mm 10 2 x8 3 x5 9 Weight 2 0 kg 4 3lb Environmental Operating Temperature 41 to 113 F 5 to 45 C Storage Temperature 13...

Страница 141: ...2 T M D S data 2 10 T M D S data 1 18 T M D S data 0 3 T M D S data 2 GND 11 T M D S data 1 GND 19 T M D S data 0 GND 4 n c 12 n c 20 n c 5 n c 13 n c 21 n c 6 DDC Input SCL 14 5V high impedance 22 T...

Страница 142: ...ard Mouse connector USB type B Connector Local Unit Pin Signal 1 VCC 5V Red 2 Data White 3 Data Green 4 GND Black Keyboard Mouse connector USB type A Connector Remote Unit Pin Signal 1 VCC 5V Red 2 Da...

Страница 143: ...02 09 2012 143 Serial Interface audio serial option Connector Remote Unit Connector Local Unit Pin Signal Pin Signal 1 n c 1 n c 2 RxD 2 RxD 3 TxD 3 TxD 4 DTR 4 DTR 5 GND 5 GND 6 DSR 6 DSR 7 RTS 7 RT...

Страница 144: ...l connector Audio RS232 at Dual head Local Unit Pin 1 AUDIO GND 2 RS232 GND 3 AUDIO OUT RIGHT CHANEL 4 AUDIO OUT LEFT CHANEL 5 RS232 RxD 6 AUDIO IN RIGHT CHANEL 7 AUDIO IN LEFT CHANEL 8 RS232 TxD Powe...

Страница 145: ...APPENDIX I CONNECTORS Rev 02 09 2012 145 B THOR Small Switch Unit Serial Interface switch socket DCE Pin Pin 1 5V Out 5 TxD Out 2 n c 6 RxD In 3 DSR In 7 n c 4 GND 8 n c 1 8...

Страница 146: ...THOR SSM 146 Rev 02 09 2012 C All THOR Devices Power Supply Pin Signal Inner 5V Outer GND CATx Interfaces Wiring acc EIA TIA 568A 1000BaseT Pin Pin 1 D1 5 D3 2 D1 6 D2 3 D2 7 D4 4 D3 8 D4 1 8...

Страница 147: ...LE Rev 02 09 2012 147 Appendix J Connection Cable Serial cable to connect the THOR Small Switch to CPU Pin Signal Pin Signal 1 n c 1 5V 2 RxD 2 n c 3 TxD 3 DSR 4 DTR 4 GND 5 GND 5 TxD 6 DSR 6 RxD 7 RT...

Страница 148: ...NOTES...

Отзывы: