Thor Kitchen TWC2403DI Скачать руководство пользователя страница 18

 

 

Maintenance Service and Trouble Shooting

 

 
Remedy 
Turn the refrigerator off, and make preparations for defrosting ,open the wine cooler 
glass door to let the air come in ,or use a fan to speed up air flowing so as to shorten 
the time needed for defrosting .Never strike the frost layer with any iron tools or wood 
stick in order to avoid damage to the evaporator tubing .

 

 
6) Refrigerating oil left in evaporator tubing   
Analysis of Trouble 
During the process of refrigerating cycles, a little refrigerating oil may remain in the 
evaporator tubing ,and after a longer time of operation ,if there is considerable 
refrigerating oil left in the evaporator ,the heat conduction effect will be severely 
affected ,thus causing a poor refrigerating effect. 
 
Remedy 
It is quite difficult to determine whether this trouble is caused by the refrigerating oil left 
in the evaporator tubing. Because this kind of phenomenon and other several trouble 
are tends to be confused. Generally speaking, you can make a judgment based on the 
frost formed on the evaporator .If the frost does not cover the evaporator, and 
moreover, it is loosely formed, you can make a judgment that the deterioration of 
Refrigerating effect is due to the accumulation of refrigerating oil left in the evaporator 
tubing in case no other troubles have been found. To clear off refrigerating oil left in the 
evaporator. Dismantle the evaporator, purge it thoroughly and then dry it .In case it is 
difficult to dismantle it, charge refrigerant from the evaporator inlet to wash it several 
times. then purge and dry it with nitrogen. 
 
7) Flowing obstructed in refrigerating system 
Analysis of Trouble 
Because the refrigerating system was originally not purged thoroughly, some of the 
filter screen meshes have been clogged by dirt accumulated in the filter after using it 
for a certain time of period. Thus resulting in a decrease in flow rate, and hence a 
poorer refrigerating effect. 
 
The abnormal phenomena caused by this kind of slight clogging in the system are as 
follows: the gas discharge pressure is lower .the temperature of discharged gas drops 
down .the position clogged has a temperature lower than that in normal conditions, and 
for a severe clogging, even dew condensation as frosting may appear. 
 
Remedy 
Purge the tubing, and after replacing the dry filter with a new one or clearing it 
thoroughly, recharge the system with refrigerant and seal the charging port. 

 
B. No Refrigerating

 

The phenomenon that the compressor runs normally. but no frost (or only a little frost ) 
appears on the evaporator ,and the refrigerator temperature does not drop down is 
called "no refrigerating". There are many causes for this trouble and it is relatively 
complicated, in servicing. Special attention to finding direct causes for this 
phenomenon. Three main potential causes for this trouble are analyzed below: 
 
1) All refrigerant in the system has leaked out 

19 

Содержание TWC2403DI

Страница 1: ...Wine Cooler Service Manual Models TWC2403DI Features Energy efficiency Micro foam technology Low noise operation Thick insulation for enerqv efficiency Version number 00 00 Edition 2019 5 20...

Страница 2: ...1 CONTENT 1 Content 2 2 Specifications 3 3 Safety precautions 4 4 Function Schedule 7 5 System Flow Chart 8 6 Circuit Diagram 9 7 Maintenance Service and Trouble Shooting 10 8 List of Parts 28 2...

Страница 3: ...Color Black Power Supply V Hz 110 60 Rated Input Power W 370 Power Consumption kW h 24h 1 3 Net Weight Lbs 264 Gross Weight Lbs 286 Unit Dimension 60 68 5 187 W D H CM Packing Dimension W D H CM 66 7...

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...Function Page Function Schedule Energy efficiency Micro foam technology Low noise operation Thick insulation for energy efficiency 7...

Страница 8: ...low Chart 2 Brief Description of System Flow Chart Model TWC2403DI is a fan cooling double system wine cooler When the wine cooler is just powered on the refrigerant flows in the sequence Compressor C...

Страница 9: ...n of Control Principle Model TWC2403DI is the direct cooling double system Wine Cooler an electronic type of all the control is generally adopted The display control PCB directly controls the start an...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...refrigerator This is a normal sound produced by the pull in or release of the armature of a current deadweight start relay when starting the compressor The compressor motor will produce a slight and...

Страница 14: ...ious welding points for leaks if leakage occurs an oil stain can be seen definitely b Check the suction and exhaust pressure values high pressure and low pressure of compressor to see whether they are...

Страница 15: ...er the compressor has operated normally for 5 10 minutes Touch and feel the condenser the temperature of its upper part should be higher than that of its lower part or its right part is hotter than it...

Страница 16: ...outlet of the capillary and no frost or a smaller quantity of loose frost appears on the evaporator After shut down the balance pressure in the system is usually lower than the saturation pressure cor...

Страница 17: ...utes open the tubing evacuate it and then recharge the system with refrigerant 4 Low efficiency of compressor Analysis of Trouble Low efficiency of a refrigerating compressor refers to the actual redu...

Страница 18: ...left in the evaporator Dismantle the evaporator purge it thoroughly and then dry it In case it is difficult to dismantle it charge refrigerant from the evaporator inlet to wash it several times then p...

Страница 19: ...gerating system has been performed improperly the effect of air purging for the whole system is not good or the water content in the refrigerant is out of standard all these will cause the expansion v...

Страница 20: ...s been used for a longer time or by the dirt accumulated gradually inside the filter Sometimes tapping the filter nay cause a passage for flowing touching it with your hand you will feel that it is co...

Страница 21: ...rouble The residual air in the system will circulate together with the refrigerant in the system The major symptoms caused by this residual air is higher gas discharge pressure higher discharged gas t...

Страница 22: ...w one 3 Sudden stoppage due to other causes Normal Stoppage Start and stop of the compressor is generally controlled by a thermostat When the temperature in the refrigerator reaches its desired value...

Страница 23: ...re sensor Remedy Remove the relay cover to check up its contacts if they are open this means that the original setting is not properly set or temperature sensing agent has leaked out of the temperatur...

Страница 24: ...upply Dirt and other impurities in the lubricant oil will increase its viscosity and cause the shaft to be seized Copper plating may also result in seizing of shaft b Seizing of piston This is caused...

Страница 25: ...temperature cannot reach its rated value the thermostat won t work thus the compressor runs continuously When the evaporation temperature in the system is too high the temperature sensing agent in th...

Страница 26: ...handle or other metal parts with your hand Test the refrigerator with a test pencil it will light up intensively measure the resistance between the power cord plug and the case body with an avometer...

Страница 27: ...ecomes weaker or vanishes If the refrigerator has not been levelly placed put a level meter on its top table and adjust the leveling screws on its legs In case noise occurs from the compressor strike...

Отзывы: