device setting.
well to ensure maximum conduction so it can reduce any high frequencies. The
copper ground wire should also be as short and thick as possible
Installer must make sure that the two ends of the ground are well conducted
and have appropriate anti-rust properties.
It is prohibited to use any other device as part of the grounding electric
circuit.
The area of the conduction between the ground wire and device’s frame
should be no less than 25
㎡
.
Chapter 3 WEB NMS Operation
You must connect the Encoder Modulator to a PC in order to setup the configuration, to
control and set configure the settings you must plug the device into web NMS Port. Users
should ensure that the computer’s IP address is different from this device’s IP address;
otherwise, it would cause IP conflict.
Login
The default IP address of this device is 192.168.0.136.
Connect the PC (Personal Computer) and the device with net cable, and use ping
command to confirm they are on the same network segment.
I.G. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx
(xxx can be 1 to 254 except 252 to avoid IP conflict).
Use web browser to connect the device with PC by inputting the Encoder Modulator’s IP
address in the browser’s address bar and press Enter.
It will display the Login interface as Figure-1. Input the Username and Password (Both
the default Username and Password are “admin”.) and then click “LOGIN” to start the