3 SpeedTouch™ Web Interface
E-SIT-CTC-20030605-0003 v1.0
42
NAPT
C
licking this button displays the Network Address and Port Translation (NAPT) page.
This page allows you to:
•
View or add/delete specific static NAPT entries:
To add static NAPT entries proceed as follows:
1
Click
New
.
2
Specify the outside address and inside address for the entry as well as the
protocol and port to which the entry applies.
Note
If the NAPT entry is applied to a connection's dynamically assigned
local peer IP address, you should specify 0.0.0.0 as the outside address.
3
Click
Apply
to add the entry to the table.
You can also add static NAPT entries semi-automatically using the SpeedTouch™
NAPT Manager. For more information on NAPT Manager, see
“4 SpeedTouch™
NAPT Manager” on page 51
.
•
View or add/delete Multi-NAT entries:
To add Multi-NAT entries proceed as follows:
1
Click
New
.
2
Specify the inside address and put the desired range between brackets e.g.
10.0.0.[1-10]. Specify the outside address and interface.
3
Click
Apply
.
Содержание SPEEDTOUCH 605S
Страница 1: ...SpeedTouch 605s Business SHDSL Router Setup and User s Guide Release R4 2 600 SERIES...
Страница 2: ......
Страница 3: ...SpeedTouch 605s Setup and User s Guide Release R4 2...
Страница 24: ...1 SpeedTouch Installation E SIT CTC 20030605 0003 v1 0 20...
Страница 54: ...3 SpeedTouch Web Interface E SIT CTC 20030605 0003 v1 0 50...
Страница 60: ...4 SpeedTouch NAPT Manager E SIT CTC 20030605 0003 v1 0 56...
Страница 68: ...5 SpeedTouch System Software Upgrade E SIT CTC 20030605 0003 v1 0 64...
Страница 72: ...6 Troubleshooting E SIT CTC 20030605 0003 v1 0 68...
Страница 73: ......