33
First issue 09 /03
GET commands
What are GET commands?
- They are commands used for TXD output of adjustment data and the like from the plasma display’s built-in microcomputer
to a personal computer.
- Adjustment data, etc., is output in ASCII code.
NOTE: Command names are given inside brackets < >.
- Data output format
NOTE: STX (02hex) Data Data ···· Data ETX (03hex)
<GPS> (GET POSITION DATA) – SCREEN adjustment data will be output as follows.
<GWB> (GET W/B DATA) – PICTURE and WHITE BALANCE adjustment data will be output as follows.
Order Data
Size
Remarks
1 H.POSITION
3byte
2 V.POSITION
3byte
3 CLOCK
3byte
(NOTE)
4 PHASE
3byte
(NOTE)
5 V.SIZE
3byte
(NOTE) If the current input signal is a video signal or digital RGB signal, the
adjustment data will be output as dummy data.
Order Data
Size
Remarks
1
2
3
4
5
Dummy data
3byte
CONTRAST
3byte
Dummy data
3byte
BRIGHT
3byte
Dummy data
3byte (NOTE)
6
COLOR
3byte
7
Dummy data
3byte (NOTE)
8
TINT
3byte
9
Dummy data
3byte
10
R HIGH
3byte
11
Dummy data
3byte
12
G HIGH
3byte
13
Dummy data
3byte
14
B HIGH
3byte
15
Dummy data
3byte
16
R LOW
3byte
17
Dummy data
3byte
18
G LOW
3byte
19
Dummy data
3byte
20
B LOW
3byte
21
H.ENHANCE (H.SHARP)
3byte
22
V.ENHANCE (V.SHARP)
3byte
(NOTE) If the current input signal is from a personal computer, the
adjustment data will be output as dummy data.