Hour Meter
The time when the total operated is counted.
This item counts the drive time of a panel.
The unit of drive time is 1 hour.
It can display for a maximum of 99999 hours.
At the time of factory shipments, it is 0H.
Version
The version of a firmware is displayed.
It is the following for details:
AAA: The version of a MAIN microcomputer
->The microcomputer that mainly controls a user interface
BBB: The version of a WIDE microcomputer
->The microcomputer that mainly controls scale conversion and I/P conversion of an image
CCC: The version of a WIDE flash memory
->The font data for OSD is mainly stored.
DDD: The version of a MODULE microcomputer
->The control microcomputer of a PDP module.
EEE: The version of a PANEL microcomputer
->The microcomputer for control of a panel.
FFF: The version of a PANEL flash memory
->Control sequence data of the PDP panel
Each item is expressed with a number and an easy sign. The part of this model with peculiar MAIN microcomputer and WIDE FLASH
memory.
FACTORY MODE
In this mode, adjustments necessary after changing assemblies can be made.
This mode is operated with RS-232C commands sent from the connected PC. To enter this mode, transmit the "FAY" RS-232C
command in Normal Operation mode.
To return to Normal Operation mode, transmit the "FAN" RS-232C command or press the MENU key on the remote control unit.
RS232C
Specification
Connector D-sub 9 pins
1
6
9
5
Pin No.
Signal
1
NC (not connected)
2
TxD (Transmit Data)
3
RxD (Receive Data)
4
NC (not connected)
5
GND (CTS)
6
(Not connected)
7
NC (not connected)
8
V+(RTS)
9
NC (not connected)