IFC228 PLASMA
First issue 10 / 04
11
FFI - Bit
Switch 2nd Tuner to Main
Fast Filter (IF / PLL)
Asia
Europe
The current signal on the second tuner is
switched to the main screen and the AV1
output.
Changing program/channel on main tuner, the
main screen stays on the second tuner.
Switch 2nd Tuner to Main enable
Switch 2nd Tuner to Main disable
Note :
Video settings
Restore Factory Settings
Developpement Support
Clear Progs.
Default Presets
Closes the sub-menu and returns to the
"Main Service Menu"
Return
Press </>: remote control; Vol. +/- : TV keyb.
MISCELLANEOUS
Clears all programms stored in memory and
resets all Picture and Sound settings to the factory
defaults. The AUTO INSTALL (out of factory)
mode can be initialised by a long press (>2s.)
of the selection button.
Sets the default (ROM) value for all the factory
sound and picture presets.
Clear Progs enable
Clear Progs disable
Default Presets enable
Default Presets disable
Factory adjusted
Restores the correct "out of box" condition.
Some settings will be restored from a
reserved backup NVM area and others will be
defaulted from the ROM.
MISCELLANEOUS
Soft-Ver V1.00*
Bus Quiet
In "Bus Quiet", the NVM can be read, modified
and reprogrammed by means of a NVM
Programmer.
To access "Bus Quiet" : Long press ">".
The TV should remain in "Bus Quiet" mode
until either Exit, Left, Right, Up,Down or
Standby keys on the RCU or local keyboard
are pressed; at which point the TV should
carry out a warmstart in order to prevent
differences between the NVM and RAM
contents.
After returning from Bus Quiet, the software
checks the NVM content.
If it is not valid, the software perform a new
default writing of the NVM content.
Bus quiet enable
Bus quiet disable
Internal ADC Calibration
Factory reset
Test pattern
Selects the PC field service menu with VGA
as input source: TV in AV4, PC AV source.
The signal must be connected to VGA port
Start the automatic ADC alignment routine.
Insert a grey test pattern
Select ADC calibration and press left or right
button. Alignment will be carried out automatically.
When complete the word "done" will be displayed.
Menu service can be re- entred via Blue button.
Scaler PC
Selects the PC field service menu with DVI as
input source: TV in AV5, DVI AV source.
The signal must be connected to DVI port.
Scaler DVI
ADC calibration (Ext. ADC)
Triggers the scaler internal ADC alignment routine.
Grey scale test pattern input :
- to VGA port for Scaller PC
- to DVI port for Scaller DVI
When complete the word "Done" is displayed.
Moving the cursor away will automatically
erase the word and ready the system for
another calbration is required.
Displays the internal test pattern.
The ">" button toggles through the colour :
White, Black, Red, Green and Blue.
After the last pattern the main menu is displayed
Displays the video submenu below.
Reset to factory values.
If not test pattern connected and when the item
return is selected the message "No signal PC"
is displayed.
To return at the Service menu it's necessay
to press a numeric button ant then the
Blue button
Depending on user selection, the changes will
either modify PC VGA or PC DVI RGB
settings.
UP
DOWN
SELECT/CHANGE
MISCELLANEOUS
Return
UP
DOWN
SELECT/CHANGE
Return
Soft-Ver V1.00
Internal ADC Calibration
....
Factory reset
....
Test Pattern
....
Video settings
....
Clear Progs
Default Presets
Bus Quiet
Development Support
Restore Factory Settings
FFI-Bit
Switch 2nd Tuner to Main
ADC Calibration
Return
Red
Green
Blue
Peak white adjustment
191
190
194
Scaler PC
Scaler DVI