![THOMSON 37PB220S4 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/thomson/37pb220s4/37pb220s4_service-manual_1109690010.webp)
IFC228 PLASMA
10
First issue 10 /04
1- The last five error codes are stored and
displayed with a time stamp from the run time
counter
2- If an error occurs that is already in the list
the time stamp is updated .
3- The errors are displayed with the most recent
error on top of the list. The others follow with
descending time stamps.
Displaying Error Codes with LED:
1- In addition to storing an error code it must
also be displayed with the TV's Standby LED.
Only the last error that occured is displayed.
2- Decimal error codes from 11 to 99
(with second digit not being 0) are signalled.
3- The error code is displayed as two separate
digits separated by a suitable pause, this is
repeated until the either the TV fixes the fault
or the TV is repaired.
For example Error-code : 23 will be displayed
thus :
2 flashes and a short pause
3 flashes and a long pause
.........
List of Error Codes : see table
To clear all event codes stored in the
NVM. Action:
Long press (> 2.5sec.).
Clear Event Codes
CODE
Press </>/OK: remote control.
EVENT HISTORY
Closes the sub-menu and returns to the
"Main Service Menu"
Return
Press </>: remote control; Vol. +/- : TV keyb.
Closes the sub-menu and returns to the
"Main Service Menu"
Return
Press </>: remote control; Vol. +/- : TV keyb.
SOUND SETTINGS
Adjust "Sound settings" registers according
to the TV environments (refer to the below table)
when the NVM memory has been replaced.
On entering this menu the sound mode will be
switched to normal and the "Dynamic Bass"
feature activated.
Effect Strength (MED)
3F
Effect Strength (HIGH)
43
Low Pass Frequency
08
High Pass Frequency
04
Sub-woofer corner Freq.
14
After setting
Store (+)
After setting
Store (+)
After setting
Store (+)
EVENT HISTORY
000000:00
Clear Event Codes
Code Count Time Stamp
Return
15 005 000000:06
00 000 000000:00
00 000 000000:00
00 000 000000:00
UP
DOWN
SELECT/CHANGE
SOUND
Return
Effect Strength (MED)
Effect Strength (HIGH)
Low Pass Frequency
High Pass Frequency
80
9A
80
56
Sub-woofer Corner Frequency 80
Store
Restore
Defaults
11
I2C bus_1 data line held low
12
I2C Bus_1 clock line held low
13/95 I2C Bus_2 data line held low
14/95 I2C Bus 2 clock line held low
15
I2C Bus_3 data line held low
16
I2C Bus 3 clock line held low
17
I2C Bus_4 data line held low
18
I2C Bus 4 clock line held low
19
Invalid chassis detected
25
Main tuner doesn't answer anymore
26
Secondary tuner (PIP) doesn't answer anymore
27
IX300 (TEA6415C) doesn't answer anymore
28
IV300 (TA1360) doesn't answer anymore
29
9V IV300 Power down detection
41
IA001 (MSP) doesn't answer anymore
42
The reset bit IA001 (MSP) is active
45 Wrong MSP is fitted
48
PIP FI doesn't answere anymore
49
5V PIP FI Power down detection
54
NVM IR005 (M24C64) doesn't answer anymore
55
IR006 (PCF8574) doesn't answer anymore
58
Code validation failed
59
Wrong IR001 is fitted
61
5VON not present
63
Unexpected level on NMI line found
69
H/V Synch. for OSD missing
72
IX400 (CXA2151) doesn't answer anymore
93
IR001 : Err_I2C Bus_1 and Err_I2C Bus_2 (Bus drivers)
94
IR001 : Err_I2C Bus_3 and Err_I2C Bus_4 (Bus drivers)
95
IR001 : Err_I2C. Port driver can not be installed
96
IR001 : ADC driver can not be installed
97
IR001 : AV-link driver can not be installed
98
SDRAM (IR110) Problematic SDRAM timing
99
IR001 Watchdog hit