![THOMSON 26LB040S5/U Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/thomson/26lb040s5-u/26lb040s5-u_manual_1110120022.webp)
EFC031E - IFC130
16
First issue 02 / 06
4.1 ADC Calibration
- Not used in this Menu.
The ADC Calibration adjustment is done in the ”PW218 1st page” (see § 1.4).
4.2 Test pattern
To check the Scaler Board:
- Press ”Left ” or ”Right ” key on RCU activate the purity test patterns in the following order:
Continous, white, black, red, green, blue, off.
5 -PW218 1st page - PW218 2nd page
- PW2300
(
spécific
IFC130)
NOTE :
The Analog RGB Calibration and YCbCr Calibration items are described at §1.4.
Except other indication the following items , only deal with factory adjustments. Their
meaning is given for information only.
5.1 - PW218 1st page
Panel Selection
- Different panel timing selection.
Factory adjust.
If this item is modified, set it to the previous value (009) then exit from the Service Mode and enter again.
(
Return
Panel
Selection
009
Analog RGB Calibration
YCbCr Calibration
Factory Reset
BW
Expand
000
CUEC / ICP
001
FRMEC
001
Flestone Correction
000
Film
Mode
000
3:2 Film Sensitivity
000
2:2 Film sensitivity
004
Pixel
Boost
000
DCS
000
DCTI
000
Peaking 001
Spatial noise Filter
000
LumaTemp.Noise Filter
064
LAI
000
Service Menu
BL1.41
Return
Sound
Video
SAA7117AE
...
...
...
PW2300
...
Misc
...
PW218 1st page
...
PW218 2nd page
...
!