![THOMSON 26LB040S5/U Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/thomson/26lb040s5-u/26lb040s5-u_manual_1110120018.webp)
EFC031E - IFC130
12
First issue 02 / 06
1.4
VIDEO CALIBRATION
1.4.1 YPbPr Calibration for TV display format
IFC130
- Connect Y, Pb, Pr signal to BV600 (”Video Components Enter”) with the following standard.
- Exit temporary from Service Mode and select the ”Video Components Enter” (press the magenta key on the
RCU ”Text” to come back at the service mode )
- Video pattern to calibrate
- Select ”YPbPr Calibration” in the ”PW218 1st page” Menu of the Service Mode and press the OK key on
the RCU.
The screen is flashing few minutes and stable after few seconds.
Signal
Valeur (Vp-p)
Y: Sync to teak white
0.7
Pr:Sync to teak white
0.7
Pb:Sync to teak white
0.7
Calibration Pattern Color bar with no Gamma correction
Picture
Format
720p60Hz, 2H, 16:9
(
Return
Panel
Selection
009
Analog RGB Calibration
YCbCr Calibration
Factory Reset
BW
Expand
000
CUEC / ICP
001
FRMEC
001
Flestone Correction
000
Film
Mode
000
3:2 Film Sensitivity
000
2:2 Film sensitivity
004
Pixel
Boost
000
DCS
000
DCTI
000
Peaking 001
Spatial noise Filter
000
LumaTemp.Noise Filter
064
LAI
000
Service Menu
BL1.41
Return
Sound
Video
SAA7117AE
...
...
...
PW2300
...
Misc
...
PW218 1st page
...
PW218 2nd page
...