![THOMSON 26LB040S5/U Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/thomson/26lb040s5-u/26lb040s5-u_manual_1110120011.webp)
EFC031E - IFC130
First issue 02 / 06
5
1.4
Video Calibration
EFC031E
1.4.1 MST9883 ADC Calibration
YPbPr Calibration for TV display format
- Connect Y, Pb, Pr signal to BV280 connector (”Video Components Enter”) with the following standard.
Input signal parameters:
- Exit temporary from Service Mode and select the ”Video Components Enter” (press the magenta key on the
RCU ”Text” to come back at the service mode )
- Video pattern to calibrate
- Select YPbPr and ”Calibration” in the ”Miscelaneous” Menu of Sevice Mode and press on
the RCU OK key .
The screen is flashing few minutes and stable after few seconds.
Signal
Value (Vp-p)
Y: Sync to Peak white
0.7
Pr:Sync to Peak white
0.7
Pb:Sync to Peak white
0.7
Calibration Pattern Color bar with no Gamma correction
Picture
Format
480p60Hz, 1H, 4:3
(
Factory Misc
(Reset the values to ROM default Yes?
LUMA_TEMPORAL-NR
CHROMA_TEMPORAL-NR
Calibration ...
Debug ...
Reset the Alignment values Yes?
TT 27Y24 Packet Enable*
Factory setting
EFC031_X181-0
Return
Sound
Video
Field Service
* According software version
...
...
...
...
Miscellaneous
...