Installation and Operating Manual
Stratotimer ST3
31-20-01
Page 404
REMOVAL / INSTALLATION
Revision: 1.00
12/06/2020
2.6 Installation
Refer to Figure 401.
(1) If necessary, remove the protective caps from the electrical connectors of the aircraft
and the Stratotimer ST3 (1).
(2) Make sure that the electrical connectors for the Stratotimer ST3 and the aircraft are
clean and undamaged.
(3) Connect the Stratotimer ST3 (1) with the aircraft electrical connector.
(4) Carefully put the Stratotimer ST3 (1) in the clamp (2).
(5) Tighten the two adjusting screws (3) on the clamp (2).
NOTE: The two adjusting screws (3) are larger than the two mounting screws (4).
2.7 Close-up
(1) Do a bonding resistance test (ref. AMM, Chapter 24).
NOTE: Electrical grounding of the Stratotimer ST3 is with the 3ATI ARINC clamp. The
conductivity resistance between the housing of the Stratotimer ST3 and the
3ATI ARINC clamp should be not more than 10 m
Ω
.
(2) Remove the tag and close the applicable circuit breaker for the Stratotimer ST3 (ref.
AMM, Chapter 24).
(3) Do an Operational Test of the Stratotimer ST3 (ref. page block 501).
(4) Remove all tools and materials and clean the work area.
Содержание STRATOTIMER ST3
Страница 3: ......