4
• Do not connect the device to any dimmer pack.
• Do not look directly at the LED light beam while the fixture is on.
• Hot lamp explosion hazard. Do not open the unit within five minutes
after switching off.
• Do not start the unit without bulb enclosure or when the housing is
damaged. The housing, the lenses, or the ultraviolet filter must be
replaced if they are visibly damaged.
Rigging the fixture
•
The unit should be mounted via its screw holes on the bracket. Always
ensure that the unit is firmly fixed to avoid vibration and slipping while
operating. Always ensure that the structure to which you are attaching
the unit is secure and is able to support a weight of 10 times of the
unit’s weight. Also always use a safety cable that can hold 12 times of
the weight of the unit when installing the fixture.
• Installation needs to be carried out by qualified people only. The device
should be installed out of reach of people and outside areas where
persons may walk by or be seated.
2. Technical Specification
• Power supply
Supply voltage:
AC 230V 50HZ
Power consumption:
260 W
• Fuse
Fuse: 20mm glass 250V T5A
• Bulb
ELC 24V 250W
• Dimension
328 x 266 x 144 mm
• Weight
4.5 kg