7-7
CKRF
7. Installation and Operation
7.
Installation and Operation
7. Installation and Operation
7-5
Base mounting method
[Standard base (Tap hole specification)]
Note)
Secure the actuator using all the mounting holes.
Note)
Use the bolt with the most appropriate length. See Table 1 for details.
Fit length
Mounting surface
Bolts for securing base
Fig. 4 Drawing for mounting CKRF4/5 tap specification
7. Mount the housing A cover.
Mounting bolt
Model number
Bolt size
Tightening torque [N·cm]
CKRF4
M2.6 × 4L
30
CKRF5
M3 × 5L
76
CKRF6
M2.6 × 5L
30
Bolt type: Thin head (FH type) head screws
www.thk.ru