5. When mounting the motor after mounting the intermediate flange to housing A.
Mount the intermediate flange onto the housing A.
Intermediate flange types and the bolts used are shown in the following table.
Mounting bolt
Model number
Intermediate flange type
Bolt size
Tightening torque [N·cm]
CKRF6
P,Q,T,U
M3 × 8L
125
Bolt type: Hexagonal-socket-head type bolt
And then, mount the motor and coupling assembled in procedure 2 onto the intermediate flange.
Mounting bolt
Model number
Motor models
Bolt size
Tightening torque [N·cm]
CKRF6 TS4603 (Tamagawa Seiki Co., Ltd.)
M4 × 10L
329
6. Secure the coupling and ball screw shaft.