Gas connection
The cooker must be connected to the gas supply with upstream connection of an
isolation valve in accordance with the respectively valid requlations. We
recommend that the isolation valve be fitted prior to the cooker to enable isolation
of the cooker from the gas supply. The valve must be easily accessable at all times
To find out the factory set gps type, see label at rear of cooker
The gas connection is via 1/2" compression. Connect the cooker to the gas supply
and check for gas soundness. NEVER use a naked flame to check for gas leaks.
Gas inlet (mm)-
Nat gas
Gas inlet (mm)- LPG
From RH rear side: 35
mm
From RH rear side: 35mm
Up from floor: 590 mm
Up from floor: 675 mm
Gas inlet with different leg heights – mm
Min NG: 560
LP: 645
Ref NG: 590
LP: 675
Max NG: 595
LP: 680
Energy consumption
Burners
Gas type
Pressure (kPa)
Injector
(mm) Mj/hr
Watts
Small
Natural
1.0
0.90
4.00
U-LPG
2.75
0.54
3.75
Medium
Natural
1.0
1.18
7.12
U-LPG
2.75
0.70
6.20
large
Natural
1.0
1.55
12.5
U-LPG
2.75
0.92
11.25
Wok
Natural
1.0
1.65
13.0
U-LPG
2.75
0.98
13.0
Oven/Grill
3000 W