background image

Electric power supply / cable connection to the aircraft system (12 Volts)

The best connection is solder with additional shrinking of the soldering joint with a shrink hose (enclosed). Only use solder for 
electronic soldering  never use cored solder. It contains acids which cause corrosion!

Important notes 

Carefully mount the cables inside the rudder and/or the fuselage. Connect the cables professionally to the aircraft system 

(red = positive, 

 

)

 and to a 5 Amps fuse protection. Luster terminals are 

black = negative

blue = radio control,

green = FLARM

not suitable to connect cables. There is a good selection of suitable crimp connections in various shops.

Servicing / maintenance

For additional UV protection, use varnish. Should the ACL be scratched, use a good polish to refurbish the damages. With 
slightly  deeper  scratches  use  wet  sandpaper  with  very  fine  granulation  (800-1000)  carefully  polish  again.  Do  not  use 
aggressive chemicals like gasoline or solvent.

For day to day cleaning use soap water!

Some insect removers and detergents forces embrittlement of epoxy based plastics and laminates. Use only aircraft certified 
products.

 If the aircraft can not hangarized, please cover the lamps to prevent surface aging!

Pasting

Apply only as much silicone as required to paste the ACL plane (see illustration 2). After fixing the ACL to the required position, 
slightly tighten the screw. With your moistened finger using dish liquid clean off any laterally dispensable silicon, a smooth 
transition can be modeled between the wing and the ACL.
Silicone needs time to cure (vaporization of acetic acid). The best results are achieved at a temperature of 20° Celsius (68° 
Fahrenheit). Just follow the handling instructions of the silicone. The final firmness (stability) will be reached after a few days.

Illustration 2

apply silicone here

apply silicone here

lateral view

lateral view

mounting at the bottom of the fuselage

mounting on top of the fuselage

Technical data

 

Operating voltage :  10-17 volts (DC), typically 12.8 - 13.4 volts
Input 

:  approx. 8 watts

Fuse 

:  5 ampere (fusible cut-out or automatic fuse)

Dimensions 

:  61 x 44 x 39 mms 

Drill hole 

:  4.5 mm

Weight 

:  approx. 85 grams with connecting cables

Warranty

 

:

 

5,000 operating hours or max. 3 years

5.000 hours or max. 3 years

assured luminous duration

Made in Germany

Im Tiegel 9

36367 Wartenberg 

Germany

Tel.: +49 (0) 66 41 - 979 - 0

eMail: [email protected]

www.thiesen-electronics.com

www.flugzeuglichter.de

THIESEN

E L E C
TRONICS
G M B H

Wiring diagram:

Verdrillte Leitungen / twisted cable 

=

Subject to changes without notice

+

_

12 Volt Battery

Fuse 5 A

Switch

Anti Collision Light

5

4

3

2

1

9

8

7

6

Power-FLARM-Output

Remote
control
output

1 - 2 ms

Switching contact

Or

ACL-UAV-12V

Отзывы: