Remote Control Command Codes
13
This information is provided for developers of automated systems. It is not relevant to most users.
Function
Allowed
RS-232 code * RC5 code (Dec)
values
(## = values)
Command **
Next
SS00NT
10
Previous SS00PV
11
Increase SS00IC
12
Decrease SS00DC
13
Store#
0-6 ‡
SS##SO
14+#
Recall#
0-6 ‡
SS##RL
21+#
Augment
SS00AG
28
Crossover
SS00XO
29
Mono
SS00MN
30
Stereo
SS00SE
31
#subs
1-16
SS##NU
31+#
Amp gain
20-40
SS##AN
48 §
Sealed
SS00SD
49
Reflex
SS00RX
50
LF limit
20-90
SS##LT
51 §
Sens
83-95
SS##SN
52 §
Damping
5-9 †
SS##DM
48+#
LF ext
15-40
SS##ET
58 §
LF level
0-12 ††
SS##LL
59 §
XO Freq
40-99
SS##XF
60 §
LFE level
0-10
SS##LE
61 §
Digit
0-9
0-9
* RS-232 port protocols are: 38,400 Baud, 8 data bits, 1 stop bit, no parity.
‡ Values of 1 to 6 execute a direct store or recall to that memory.
A value of 0 initiates the command. For completion, increase or decrease
commands select which memory, and a second store or recall completes the command.
† Multiply desired setting by 10. Example: setting of 0.7 = value of 7.
†† Add 6 to the desired LF setting. Example: setting of zero = value of 6.
§ These commands must be followed by two digit commands or the sequence is aborted.
** RC5 system value depends on DIP switch settings:
Switch settings
System
DIP switch settings must be the same in the Integrator and the Remote control un
on-on-on-on
7
The DIP switches are accessed by removing the top cover of each unit.
on-on-on-off
11
on-on-off-on
14
on-on-off-off
15
on-off-on-on
17
on-off-on-off
18
on-off-off-on
19
The RC5 code is a 14 bit word that is built with
on-off-off-off
20
a start bit of “1”, a second bit of “0”,
off-on-on-on
21
a toggle bit that changes with each new key press,
off-on-on-off
22
5 “system” bits and then 6 “command” bits.
off-on-off-on
23
In decimal notation, this is 16,384, plus 64 times
off-on-off-off
24
the system value, plus the command value,
off-off-on-on
25
with 4096 added to each alternate key press.
off-off-on-off
26
off-off-off-on
27
off-off-off-off
28
EXAMPLES
System*
Function
RS-232 code
1
st
2
nd
3
rd
1
st
2
nd
3
rd
Recall preset 4
SS04RL
25
25
4659
–
–
Set XO Freq to 65
SS65XF
25
60
6
5
467C
4646
4645
Set LF Level to +3
SS09LL
25
59
0
9
467B
4640
4649
* If DIP switches set to off-off-on-on.
** Assuming toggle bit = 0.
RC5 word (hex)**
Command
RC5 code (Dec)