Installation /Owner’s Manual 19
!
1. Using the following chart, decide which vents and rough opening (RO) sizes to use:
Certified Vent
P/N
RO Height
RO Width
Upper Roof Exhaust Cap
622293
N/A
N/A
Upper Roof Exhaust Vent
616319
610mm
133mm
Upper Exhaust and
631140
249mm
490mm
lower Intake Side Vent
2. Install the lower intake vent (See Art02264, Art02265, and Art02266):
NOTE: The lower intake vent is also the service access opening for the
components on the rear of the refrigerator.
WARNING:
Make sure the bottom of the opening of the lower intake vent
is even with or immediately below the floor level. This allows any leaking
propane gas to escape to the outside and not to collect at floor level.
- Make sure the bottom of the opening of the lower intake vent [9] is even with or
immediately below the floor level.
Install the Lower and Upper Vents
10
19
17
Art02264
18
9
19
16
11
13
16
12
15
14
Art02265
14
12
13
16
11
20
19
19
17
18
10
9
16
Art02266
9
11
10