Winterization
This toilet must be winterized to avoid
freeze damage. Failure to do so will void
warranty.
1) Drain RV’s potable water supply.
2) Flush all of toilet’s plumbing with RV-type anti-
freeze (Propylene Glycol).
Refer to your vehicle manufacturer’s
winterization procedure for further informa-
tion.
Trouble Shooting
1)
Leaks
:
a) Back of toilet: check water supply line connec-
tion.
b)
Between closet
fl
ange and toilet:
check
Screws for tightness. If leak continues, remove
toilet and check
fl
ange height. Adjust, if neces-
sary, to 7/16” above
fl
oor. Replace
fl
ange seal
if damaged.
2)
Bowl will not hold water:
Check for and
remove foreign material in valve blade groove
in the
fl
ush drain. If necessary, replace blade
seal.
3)
Poor
fl
ush:
A good
fl
ush should be obtained
within 2 to 3 seconds. If problem persists,
remove the water supply line and check
fl
ow
rate. The
fl
ow rate should be at least eight
quarts (7.6 liters) per minute.
4) Flush or Add Water stops after 10 seconds
(Aria Deluxe II only):
an automatic shutoff is
normal.
5) No electric operation (Aria Deluxe II only):
check for blown/broken fuse. If needed, replace
with a 4-amp Slow-Blow Fuse (Littlefuse 4-amp
3AG Slow-Blow or Thetford Part #19630). Fail-
ure to use the proper fuses and/or connections
may result in damage to the Toilet or the RV
and void the Warranty.
CAUTION: To avoid breaking glass fuse,
pull fuse holder STRAIGHT apart. Do not
bypass the in-line fuse supplied with
the toilet.
Manual override
In the event of a power outage, the
contents of the bowl can be released
to the holding tank by opening the
valve manually using the overrride
knob on the back of the toilet. Turn
clockwise to open, counter-clockwise
to close.
Back of Toilet
Deodorizing
This toilet was designed to be compat-
ible with Thetford brand holding tank
deodorants.
Cleaning
Use Thetford
Aqua-Clean
TM
non-abrasive
cleaner with a soft-bristle, non-abrasive
bowl brush, sponge or soft cloth. DO NOT
USE SCOURING POWDERS, ACIDS
OR CONCENTRATED CLEANERS,
WHICH CAN DAMAGE SURFACES,
PLASTIC PARTS AND RUBBER SEALS.
FAILURE TO DO SO CAN VOID YOUR
WARRANTY.
Installation
Please read entire instructions before
attempting installation.
Items Needed for Installation:
• Drill with
3
/
16
-inch bit
•
1
/
2
” Carbide drill bit with Locking Ring
(if mounting on ceramic tile)
•
7
/
16
-inch Wrench (Socket or Ratchet)
• Adjustable Wrench
• Silicone Caulk (RTV)
• Tool to cut carpeting/padding (if needed)
Aria DeLuxe II only:
• Wire Crimper • Wire cutting pliers
Plumbing required:
For adequate flush, a 3/8” (min.) water
supply line with good
fl
ow is required.
Procedure (all models)
1. Unpack new toilet. Check for shipping damage.
2. Make sure RV’s water supply is turned off.
3. Remove old toilet (including Closet Flange Seal
and Closet Bolts). Take necessary precautions
when handling and disposing of soiled toilet.
4. Install new Closet Flange Seal (found in Bolt
Pkg.) to bottom of new Toilet with lip oriented
down.
5. Make sure top of Closet Flange is
7
/
16
” above
fl
oor surface. In some cases, the use of closet
fl
ange spacer(s) (included) may be required to
achieve this mounting height (Fig. 1).
6. If necessary, the
3
/
8
” spacer goes under the
closet
fl
ange.
Fig. 1
Aria DeLuxe II only
1. A 12-volt power line with access to the Toilet
is required.
Warning:
Thetford Corporation recom-
mends that a quali
fi
ed RV Technician or
Electrician install this toilet according to all
applicable codes and regulations. Improper
installation can result in equipment damage,
personal injury or death.
Use a 10-amp breaker or fuse when
wiring from the primary 12-volt source.
Failure to use the appropriate 10-amp
breaker, or fuse holder and 10-amp fuse,
can result in damage to your Thetford toilet,
RV, or both.
IMPORTANT: A stable minimum of 10
volts DC is REQUIRED AT TOILET CON-
NECTION point for proper operation.
If voltage is below 10 volts, re-wiring to a
more stable source such as the main breaker
panel or main battery terminal is required.
2. Installer must provide required wire and con-
nectors.
3. If wiring toilet to the main breaker panel or
main battery terminal, use a 10-amp fuse or
breaker.
4. For distances up to 20 feet from the nearest
Breaker Panel or Battery to the Toilet, use
14-gauge or 12-gauge wire. For distances
20 feet or greater, use 12-gauge.
7
/
16
”/
po