background image

Winterization

This toilet must be winterized to avoid 

freeze damage. Failure to do so will void 

warranty.

1)  Drain RV’s potable water supply.
2)  Flush all of toilet’s plumbing with RV-type anti-

freeze (Propylene Glycol). 
Refer to your vehicle manufacturer’s

winterization procedure for further informa-

tion.

Trouble Shooting

1) 

Leaks

a)  Back of toilet: check water supply line connec-

tion.

b)

Between closet 

fl

 ange and toilet: 

check 

Screws for tightness. If leak continues, remove 

toilet and check 

fl

 ange height. Adjust, if neces-

sary, to 7/16” above 

fl

 oor. Replace 

fl

 ange seal 

if damaged.

2) 

Bowl will not hold water: 

Check for and

remove foreign material in valve blade groove 

in the 

fl

 ush drain. If necessary, replace blade 

seal.

3) 

Poor 

fl

 ush:

 A good 

fl

 ush should be obtained

within 2 to 3 seconds. If problem persists,

remove the water supply line and check 

fl

 ow 

rate. The 

fl

 ow rate should be at least eight

quarts (7.6 liters) per minute.

4)  Flush or Add Water stops after 10 seconds 

(Aria Deluxe II only): 

an automatic shutoff is 

normal.

5)  No electric operation (Aria Deluxe II only): 

check for blown/broken fuse. If needed, replace 

with a 4-amp Slow-Blow Fuse (Littlefuse 4-amp 

3AG Slow-Blow or Thetford Part #19630). Fail-

ure to use the proper fuses and/or connections  

may result in damage to the Toilet or the RV

and void the Warranty.

CAUTION: To avoid breaking glass fuse, 

pull fuse holder STRAIGHT apart. Do not 

bypass the in-line fuse supplied with 

the toilet.

Manual override 

In the event of a power outage, the 

contents of the bowl can be released 

to the holding tank by opening the 

valve manually using the overrride 

knob on the back of the toilet. Turn 

clockwise to open, counter-clockwise 

to close.

Back of Toilet

Deodorizing

This toilet was designed to be compat-

ible with Thetford brand holding tank 

deodorants.

Cleaning

Use Thetford 

Aqua-Clean

TM

 non-abrasive 

cleaner with a soft-bristle, non-abrasive 

bowl brush, sponge or soft cloth. DO NOT 

USE SCOURING POWDERS, ACIDS 

OR CONCENTRATED CLEANERS, 

WHICH CAN DAMAGE SURFACES, 

PLASTIC PARTS AND RUBBER SEALS. 

FAILURE TO DO SO CAN VOID YOUR 

WARRANTY.

Installation 

Please read entire instructions before 
attempting installation.

Items Needed for Installation:

• Drill with 

3

/

16

-inch bit

• 

1

/

2

” Carbide drill bit with Locking Ring 

(if mounting on ceramic tile)

• 

7

/

16

-inch Wrench (Socket or Ratchet)

• Adjustable Wrench
• Silicone Caulk (RTV)
•  Tool to cut carpeting/padding (if needed)

Aria DeLuxe II only:

•  Wire Crimper  •  Wire cutting pliers

Plumbing required:

For adequate flush, a 3/8” (min.) water 
supply line with good 

fl

 ow is required.

Procedure (all models)

1.  Unpack new toilet. Check for shipping damage.
2.  Make sure RV’s water supply is turned off.
3.  Remove old toilet (including Closet Flange Seal 

and Closet Bolts). Take necessary precautions 

when handling and disposing of soiled toilet.

4. Install new Closet Flange Seal (found in Bolt

Pkg.) to bottom of new Toilet with lip oriented 

down.

5. Make sure top of Closet Flange is 

7

/

16

” above

fl

 oor surface. In some cases, the use of closet 

fl

 ange spacer(s) (included) may be required to 

achieve this mounting height  (Fig. 1). 

6. If necessary,  the 

3

/

8

” spacer goes under the

closet 

fl

 ange. 

Fig. 1

Aria DeLuxe II only

1.  A 12-volt power line with access to the Toilet 

is required.

Warning:

 

Thetford Corporation recom-

mends that a quali

fi

 ed RV Technician or 

Electrician install this toilet according to all 

applicable codes and regulations. Improper 

installation can result in equipment damage, 

personal injury or death. 

Use a 10-amp breaker or fuse when 

wiring from the primary 12-volt source. 

Failure to use the appropriate 10-amp 

breaker, or fuse holder and 10-amp fuse, 

can result in damage to your Thetford toilet, 

RV, or both.

IMPORTANT: A stable minimum of 10 

volts DC is REQUIRED AT TOILET CON-

NECTION point for proper operation.

If voltage is below 10 volts, re-wiring to a 

more stable source such as the main breaker 

panel or main battery terminal is required. 

2.  Installer must provide required wire and con-

nectors.

3. If wiring toilet to the main breaker panel or

main battery terminal, use a 10-amp fuse or 

breaker.

4.  For distances up to 20 feet from the nearest 

Breaker Panel or Battery to the Toilet, use

14-gauge or 12-gauge wire. For distances

20 feet or greater, use 12-gauge.

7

/

16

”/

po

Отзывы: