Transporting the Unit
4.1.1
PACK THE UNIT in an upright position for transport, using the original
packaging materials, if possible.
a
FASTEN THE UNIT to a wooden base using bolts, to keep it from moving
during transport.
b
SEAL THE UNIT in plastic with a desiccant to help protect it from rust,
corrosion, and other damage.
c
CONSTRUCT WOODEN SIDES and top to enclose the unit in a solid
protective crate.
d
PACK LOOSE PARTS in small boxes or ship separately.
4.1.2
INSPECT THE UNIT according to the Instructions for Periodic Inspection
before installing it in a new location.
4.2
Storing the Unit
4.2.1
FILL THE REDUCER with lubricant, and make sure the breather plug is
clean and properly installed. Add a rust preventative for long term storage.
Follow the reducer manufacturer’s instructions.
4.2.2
SEAL THE UNIT in plastic with a desiccant to help protect it from rust,
corrosion, and other damage.
4.2.3
STORE THE UNIT upright, in a cool clean place away from corrosive
chemicals and moisture.
4.2.4
ROTATE THE DRUM PERIODICALLY to keep bearing and gears surfaces
from becoming lacquered. Release the brake to rotate the drum.
4.2.5
INSPECT THE UNIT according to the Instructions for Periodic Inspection
before installing it for operation.
4.2.6
TEST INSULATION RESISTANCE in the motor to detect moisture
damage. Refer to the motor manufacturer’s instructions.
4.2.7
DRAIN THE REDUCER
and fill with proper lubricant prior to operation.
See section 3.2 - Lubricating the Unit.
Important!
• Keep a record of what you ship,