Correct connection of sensors causes displaying of actual CH furnace's temperature and the
temperature of useful warm water of the WUW buffer (if the function is active). On the screen
appears which function is currently used by the driver.
The burner may work in three working modes (“STOP”, “IGNITION”, “AUTOMATIC WORK”). The
mode changes when the “
MODE
/ ” button is pressed. Activating the “STOP” mode is possible
in all modes after pressing the “MODE/ ” button for 3 seconds. When Stop is activated, the
burner goes at “Burning off” process (if there is fire) and the at “Cleaning” process.
When the burner is activated for first time, it is on “Stop” mode. Every next time, its status is
saved in the regulator's non-volatile memory. Activating the driver again, automatically causes
switching on of the lately used working mode.
In the table beneath a short description of particular functions of the burner, activated depending
on the working mode of the driver, is shown.
FUNCTION'S NAME
DESCRIPTION OF FUNCTIONS
STOP
Burner stopped.
FEEDER FILLING
Filling the feeder.
Filling stops automatically after about 10 minutes.
IGNITION
The burner is on Ignition process, which mean that has fed with ignition dose
of pellet, the heating element (igniter) and the air fan are working. The mode
would be automatically changed after detecting a flame by the sensor.
CLEANING
The air fan works at full speed for one minute, to remove the remaining
ashes from the burner's fire chamber. This function takes place also at the
first minute of ignition
WORK
Heating the boiler up to the set temperature. Showing the actual power of
the burner.