INSTALLATION, USE AND MAINTENANCE GUIDE
POPSTAR 6
– POPSTAR 10
Page
32
ENG
Seal area where the inlet and outlet part of the smoke exhaust meets the wall. It is strictly forbidden to apply mesh to the end of the
outlet tube , as it could cause the appliance to malfunction.
If the smoke tube is installed in a fixed position it is advisable to provide inspection openings for clean-out purposes especially in the
horizontal sections. See the diagram. These openings are essential to allow for the removal of ash and unburned products which tend
to accumulate along the discharge path. The appliance functions with the combustion chamber in a vacuum, while the discharge of
smoke to the flue outlet has a slight pressure, consequently it is imperative to ensure that the discharge system is hermetically sealed.
The smoke exhaust pipe must be made from suitable materials such as porcelain-coated steel tubes, and the various fittings sealed
with red silicone (resistant to 350°C). The outer casing of the tube must be made with insulating material (mineral wool, ceramic fiber)
or use pre-insulated tubing. THE FLUE OUTLET MUST BE USED ONLY FOR THE APPLIANCE. It must be possible to inspect and
remove all the smoke tube sections for clean-out purposes.
ATTENTION: if the flue outlet is not sufficiently insulated and /or if it is too long it could generate condensation.
It is mandatory to provide a condensation drain near the smoke outlet of the appliance. The appliance must always
and only be installed in a single flue outlet system dedicated exclusively to the appliance. If the generator is
connected to a non-compliant flue system the appliance could rapidly deteriorate due to an abnormal, continuous
overheating: in this case the damaged parts will not be covered by warranty. IF THE CHIMNEY CATCHES FIRE DO
NOT HESITATE TO CALL THE FIRE BRIGADE IMMEDIATELY.