DATA ANALYSIS represents the function concerning update of data between the heater and the handheld radio control. The radio wave
transmission is frequently used by numerous applications: the DATA ANALYSIS function is used to update the temperature, ventilation,
power, temperature analysis, system status. The DATA ANALYSIS process can take from a minimum of 18 seconds to a maximum of 40
seconds. If the DATA ANALYSIS is not executed successfully, repeat the operation by pressing the button (19) for a few seconds then
releasing it.
5.8 TRANSMISSION - RECEPTION ALARMS
5.8 TRANSMISSION - RECEPTION ALARMS
5.8 TRANSMISSION - RECEPTION ALARMS
5.8 TRANSMISSION - RECEPTION ALARMS
5.8 TRANSMISSION - RECEPTION ALARMS
If a problem arises with the communication between the handheld radio control and the heater the following messages could appear on the
display:
OUT OF RANGE
: the radio control is located at a distance that is greater than the radio control's radius of action.
NO CURRENT
: the heater has shut down and does not appear to be powered by electricity.
PRESS A BUTTON
: if the radius of action has been exceeded, to restore communication with the heater press one of the
buttons on the radio control for approx. 2 seconds.
AVVIO
5.9
5.9
5.9
5.9
5.9 A
A
A
A
AUT
UT
UT
UT
UTOMA
OMA
OMA
OMA
OMATIC / MANU
TIC / MANU
TIC / MANU
TIC / MANU
TIC / MANUAL OPERA
AL OPERA
AL OPERA
AL OPERA
AL OPERATING MODE
TING MODE
TING MODE
TING MODE
TING MODE
5.9.1 DESCRIPTION OF
5.9.1 DESCRIPTION OF
5.9.1 DESCRIPTION OF
5.9.1 DESCRIPTION OF
5.9.1 DESCRIPTION OF THE
THE
THE
THE
THE A
A
A
A
AUT
UT
UT
UT
UTOMA
OMA
OMA
OMA
OMATIC OPERA
TIC OPERA
TIC OPERA
TIC OPERA
TIC OPERATING MODE CY
TING MODE CY
TING MODE CY
TING MODE CY
TING MODE CYCLE
CLE
CLE
CLE
CLE
In the automatic operating cycle the heater expresses its maximum flexibility of operation
while optimising fuel consumption. During the AUTO cycle the heater self-regulates the
combustion and ventilation according to the temperature (9) set by means of buttons (3) and
(4). If for example the temperature (9) is set at 23°C the heater attempts to take the room
temperature (5) detected by the handheld radio control to 23°C in the shortest possible time
by modulating power and ventilation as the room temperature approaches set temperature
(9). Once this temperature is reached the heater settles at the minimum operating value for
combustion and ventilation. To select this function press the button (1) repeatedly until the
word AUTO appears on the display (see image on the right). During the POWER ON phase,
that takes 20 minutes, the heater ignores all the commands transmitted. After this time has
elapsed the word POWER ON disappears on the delay and the word RUNNING appears :
during this phase the AUTOMATIC cycle is operational. The room fan starts operating as
soon as the heater body exceeds the 42°C threshold.
It is normal for the temperature sensor to detect temperatures which are slightly
different to the real ones: variations caused by the environment in which the ra-
dio control is positioned.
5.9.2 DESCRIPTION OF
5.9.2 DESCRIPTION OF
5.9.2 DESCRIPTION OF
5.9.2 DESCRIPTION OF
5.9.2 DESCRIPTION OF THE MANU
THE MANU
THE MANU
THE MANU
THE MANUAL OPERA
AL OPERA
AL OPERA
AL OPERA
AL OPERATING MODE CY
TING MODE CY
TING MODE CY
TING MODE CY
TING MODE CYCLE
CLE
CLE
CLE
CLE
The manual cycle is indicated by the absence of the word AUTO on the display. The
combustion and ventilation power can be controlled independently from each other by means
of the buttons (1) and (2). During the POWER ON phase, that takes 20 minutes, the heater
ignores all the commands transmitted to it. After this time has elapsed the word POWER ON
disappears on the delay and the word RUNNING appears : during this phase the MANUAL
cycle is operational. The room fan starts operating as soon as the heater body exceeds the
42°C threshold. The combustion is regulated by 5 bars, the regulation of the ventilation is
distributed on 6 steps. The room temperature thermostat is disabled when this function is
operational.
It is normal that in the manual cycle the ventilation is often set at the maximum
speed in order to cool the heater body more effectively.