INSTALLATION
page 11
4.2 MOUNTING THE OUTER CASING ON ASPIROTRONIC COMBI LE.
- Mount the outer casing to the boiler as shown
in the figure on the previous page.
- Do not mount the top front panel (2); in its
place, mount the top rear panel (3) (For LE 102
COMBI use 2 brackets as the Eura boiler,
unlike the Aspirotronic boiler, is positioned
centrally).
- Disconnect the pins from the front panel and
fasten it to the rear panel.
- Fasten the bracket C to the EURA boiler (using
screws and nuts A)
- Position the Eura boiler as illustrated in the
figure and fasten it to the ASPIROTRONIC
boiler (using screws and nuts B).
- Position the EURA boiler and adjust the height
by acting on the screws which fasten the
bracket B.
- Wrap the mineral wool (5) around the boiler,
secure it using the fasteners provided and
make holes for the feeler pockets.
- Mount panels 1 and 3 (the plug must be at the
front); insert them inside the 4 brackets on the
front panel of the boiler.
- Then mount panel 2 and secure the side panels
1 and 3 using the screws provided.
- Lastly, fasten panel 4.
Screws and nuts A, B
: M8x25 hexagon head screws and nuts
Screws and nuts C
: M10x60 hexagon head screws and nuts
Follow the diagram below to mount the outer casing of the EURA boiler. Two panels to be mounted at the
front and back of the boiler are supplied with boiler LE 102.
Содержание aspiromec le