Page
9
Manuale d'installazione, uso e manutenzione
SOFIA
– ILARIA – VITTORIA – ANNA
VISTA FRONTALE
SCALA 1:20
VISTA FIANCO SX
SCALA 1:20
VISTA POSTERIORE
SCALA 1:20
VISTA SUPERIORE
SCALA 1:20
VISTA ISOMETRICA - SCALA 1:10
NOTE PER LA NORMALIZZAZIONE:
- Quote SEMPRE in ALTO e a DESTRA
- QUOTARE SEMPRE IL "FUORI TUTTO"
poi eventuali "sottoingombri"
- Ricordarsi di rendere visibile
le linee nascoste del vetro (se presente)
- Quotatura "assiale" per viste posteriori
- Compattare le viste ortogonali il più possibile
O
13
0
455
91
4
95
1
541
14
1
455
2 – TECHNICAL CHARACTERISTICS
SOFIA
ILARIA
VITTORIA
ANNA
Height (mm)
951
1,011
1,133
1,550
Depth (mm)
541
573
573
575
Width (mm)
455
511
511
511
Weight with casing Easy (kg)
118
140
156
216
Weight with casing Ceramica (kg)
132
155
171
239
Smoke outlet diameter (mm)
130
130
130
130
Minimum draught (Pa)
12
12
12
12
Maximum permitted fuel feed Kg ***
2.6
3.3
3.8
3.8
Maximum hourly consumption (Kg/h)
***
2.6
3.0
3,5
3,5
Average load duration (Min) **
60
55
55
55
Firebox power (kW) **
11.14
13.09
14.96
14.96
Rated power (kW) **
9.07
11.13
12.76
12.91
Efficiency (%) **
81.37
85.05
85.26
86.29
CO emissions (mg/m³ at 13% O
2
) **
625
590
881
608
Heatable volume (m³) *
245
300
345
345
Average smoke temperature (°C) **
289
234
242
215
Smoke flow rate (g/s) **
6.2
7.2
7.6
8.4
Firebox feed opening dimensions (mm)
(LxH)
245x318
315x320
315x442
315x442
Firebox dimensions (mm) (LxHxD)
289x343x337
362x337x380
362x462x380
362x462x380
Oven dimensions (mm) (LxHxD)
-
-
-
344x303x333
** IMPORTANT: It is important to take into consideration the fact that the heatable volume is greatly influenced by the
insulation of the house (energy class of the building) and by the position of the appliance in the planimetry of the house,
therefore the indicated values may vary, even significantly.
** ATTENTION: The indicated values were obtained using beechwood logs (2 logs) with thermal value less than 15,429
kJ/kg and moisture content less than 15%. The use of poorer quality firewood than that specified results in lower yield and
lower efficiency, and produces more ash. Moreover the glass on the feed door will become dirtier sooner.
*** It is strictly prohibited to load a greater quantity of fuel than that specified in the table. The warranty will not cover
damages caused by the prolonged exposure of the appliance to temperatures that are too high.
2.1 DIMENSIONS
SOFIA