18
Press to turn the timer off
Press and the hold until
04
is displayed
Press and hold
for approx. 5 seconds
will display on the screen and then the
timer has been reset.
Turn the timer back on to setup the program
Factory Reset
Notes
Страница 1: ...7 Day Programmable Timer Installation User Guide TRTS TRTSB ...
Страница 2: ...lling the timer 3 User Interface 5 Setting the date time 6 Heating modes 7 Advanced settings 8 Setup your heating schedule 9 Technical data 16 Key lock 17 Temporary override 18 Service and support 20 Contents ...
Страница 3: ...g a flat head screwdriver into the slots on the bottom of the unit and push to release Unplug the cable connector from the back of the timer screen Connect the Thermorail towel rail to the timer as seen in the below wiring diagram Installing the timer ...
Страница 4: ...4 Screw the back plate of the timer to the electrical plate Plug the cable connector into the back of the timer screen and connect the screen to the back of the timer Installing the timer ...
Страница 5: ...5 User Interface 1 Day indicator 2 Key lock icon 3 Schedule mode icon 4 Manual mode icon 5 ON OFF indicator 6 Confirm settings 7 Program button 8 Mode button 9 Power button 10 Up down arrows 11 Time ...
Страница 6: ...ss and the time will begin to flash Use to select the correct time Press until the day begins to flash Note Monday is Day 1 Use to select the correct day Press to save the settings Setting the date and time ...
Страница 7: ...between manual and schedule modes Manual Mode In manual mode press the to set the ON OFF status Schedule Mode In the schedule mode the timer will follow the heating schedule that is set Refer to page 9 for programming instructions Heating Modes ...
Страница 8: ...just the settings Press to cycle between setting 01 to 03 Press to save the settings Advanced Settings Menu Description Range Default 01 Clock Format 12 or 24 24 02 5 2 or 7 Day Programming 01 5 2 Day Program 02 7 Day Program 01 5 2 Day Program 03 Screen Saver ON Activated OF Not Activated OF Not Activated ...
Страница 9: ... This is the first ON period for the day Use the to adjust the time to when the heated towel rail will turn on in the morning Press and the ON OF will flash Using the select ON for P1 Press to set period 2 which is when the rail will turn off Use the to adjust the time Set up your heating schedule For 5 2 Day Program ...
Страница 10: ...on in the evening and P4 is turning it off in the evening If the heated towel rail is only required to be on once a day set to OF for both P3 and P4 and ensure that the time set for P3 and P4 is after the time set for P2 When Monday Friday has been set press to go onto the Saturday and Sunday schedule Set up your heating schedule For 5 2 Day Program ...
Страница 11: ...ted towel rail will turn on in the morning Press and the ON OF will flash Using the select ON for P1 Press to set period 2 which is when the rail will turn off Use the to adjust the time Press and the ON OF will flash Using the select OF for P2 Repeat above steps for P3 and P4 Set up your heating schedule For 5 2 Day Program ...
Страница 12: ...days are programmed to the same schedule or all 7 days are programmed individually Press until the day display flashes If programming all 7 days individually use the to select the day to program first If programming all 7 days to the same schedule press and hold the button for about 5 seconds to select all 7 days Set up your heating schedule For 7 Day Program ...
Страница 13: ...to adjust the time the heated towel rail will turn on in the morning Press and the ON OF will flash Using the select ON for P1 Press to set period 2 which is when the rail will turn off Use the to adjust the time Press and the ON OF will flash Using the select OF for P2 Set up your heating schedule For 7 Day Program ...
Страница 14: ...d towel rail on in the evening and P4 is turning it off in the evening If programming all 7 days to the same schedule the program is now set up If programming all 7 days individually press and use the to select the next day to program Set up your heating schedule For 7 Day Program ...
Страница 15: ...15 Supply voltage 230 240VAC Maximum Load 16A IP Rating IP30 Warranty 2 Years Width 80mm Height 120mm Depth 45mm 27mm in wall Technical data ...
Страница 16: ...16 To lock the key pad press and hold the for 5 seconds or until the displays To unlock press and hold the until the disappears Key Lock ...
Страница 17: ... be operated on manual until the next programmed period In schedule mode press the and the ON OFF display will flash Use to adjust the desired setting and press to confirm will be displayed below the ON OFF display To cancel the override setting press Temporary override ...
Страница 18: ...n the timer off Press and the hold until 04 is displayed Press and hold for approx 5 seconds will display on the screen and then the timer has been reset Turn the timer back on to setup the program Factory Reset Notes ...
Страница 19: ...19 Notes ...
Страница 20: ...20 Thermogroup AU PO Box 822 Leeton NSW 2705 1300 368 631 sales thermogroup com au www thermogroup com au Service and support ...