User’s manual
GB
GB
54
In this case, make the following checks to verify that programming orders are transmitted
correctly:
Orders
Received
No
current
230V for 3s
230V for 7s
230V
-115V
négative
+115V
positive
Signal to be
transmitted
Mode
Obtained
COMFORT
COMFORT
-1°C
COMFORT
-2°C
ECO
FROST
FREE
SWITCH
HEATING
OF /
LOAD
SHEDDING
Frost free and load shedding orders take priority when programming is done through pilot
wire or power line.
The time to changeover from Comfort mode to Eco mode is of the order of 12 seconds.
1.5 - Lock the radiator on its wall-mounting frame
- Place the radiator on wall-mounting frame S as
shown on the diagram.
- Bring the radiator to the wall-mounting frame and
then lift it (arrows 1 and 2).
- Insert the wall-mounting frame tabs in the radiator
holes and then lower the radiator (arrow 3).
- Lock by turning the 2 V screws by half a turn and
your radiator is fixed.