21
EN
CONNECTINg ThE APPlIANCE
Connection rules
-
The appliance must be connected to a 230 V, 50 Hz single-phase power
supply.
-
The appliance’s power supply must be connected directly to the
network after the circuit-breaker without an intermediate switch.
-
The appliance will be connected to the mains by means of the appliance
cable via a connection box.
-
The power supply must be connected directly to the network after
the all-pole cut-off device in accordance with the installation rules.
-
If the power supply cable is damaged, it must be replaced by the
manufacturer, their after-sales service or an individual with a similar
qualification in order to avoid any danger.
Appliance wiring diagram
Switch the power off and connect the wires as shown in the wiring
diagram below:
Câble de l'appareil
Phase=marron
Neutre=bleu
PHASE
NEUTRE
Réseau
Electrique
Appliance cable
Live-brown
Neutral-blue
LIVE
NEUTRAL
Electricity
network
MAINTENANCE
This appliance is fitted with a filter to
protect the heating element against dust
and dirt.
The filter can be removed for easy cleaning
with water.
About once a month, a message will tell you
to “Clean filter”. You must then clean it.
Even when the screen displays the message indicated above, the
appliance continues to work in active mode.
If you press a button, the integrated counter is reset and the display
indicates
1
additional month of operation.