KAC/KHP/KAC-M/KHP-M Series             

Owner’s Manual

2

ThermoPlus Air, Inc.  February  2007

Data subject to change without notice.

Startup                           Supervisaire® Controller Interface

ST
ARTUP

Prg

Esc

EEsscc  

is used to

return to previous

interface levels. 

The backlit LCD screen dis-

plays any needed information
on the operation of the system.

Default screen

present value     set point       

is used to scroll

downward through
screens and to decrease
settings.

Do not press      and

at the same time.

is used to scroll

upward through screens
and to increase settings.

Do not press      and

at the same time.

is used to

navigate around
the screen and to
accept inputs.

While in the
default
screen, press
the 

Prg 

button to 
display the 
program 
version.

is used to

access the list of
alarm conditions, if
any exist.

HUMIDITY

aaa / bbb %

ROOM AIR    ccc / ddd  F

Содержание KACE Series

Страница 1: ...ting with at least one 90o elbow or provide a sound baffle between the return air grille and unit filter Horizontal units are provided with isolation hanger support See Fig 2 for proper installation w...

Страница 2: ...30 012 75 0 30 015 75 0 30 018 75 0 30 024 188 0 75 030 188 0 75 036 188 0 75 042 188 0 75 048 188 0 75 060 188 0 75 072 25 to 275 0 10 to 1 1 096 25 to 275 0 10 to 1 1 120 25 to 275 0 10 to 1 1 144 2...

Страница 3: ...ONT BLOWER AND MOTOR ACCESS PANEL RETURN AIR SUPPLY AIR WATER IN WATER OUT CONDENSATE DRAIN TUBE LOW VOLTAGE IN POWER IN BLOWER ACCESS PANEL ELECTRICAL AND COMPRESSOR ACCESS PANEL ELECTRICAL ACCESS PA...

Страница 4: ...N WATER OUT LOW VOLTAGE IN POWER IN ELECTRICAL ACCESS PANEL ELECTRICAL AND COMPRESSOR ACCESS PANEL WATER REGULATING VALVE ACCESS PANEL C Detail C 3 8 WASHER BY OTHERS 3 8 16 NUTS DOUBLE BY OTHERS 3 8...

Страница 5: ...ts box Refer to the instruc tions included Separate the display into its three pieces Thread the end of the cable thorugh the hole in the sub base as shown Using care to maintain level screw the sub b...

Страница 6: ...ration of the system Default screen present value set point is used to scroll downward through screens and to decrease settings Do not press and at the same time is used to scroll upward through scree...

Страница 7: ...setting aa I O Board address bb Default Screen HUMIDITY aaa bbb ROOM AIR ccc ddd F xxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx Prg Esc 2 Simultaneously press and hold the and buttons for at least fiv...

Страница 8: ...Read Sensors or Operation Read Sensors This screen is the gateway to other screens used for setting the operating set points of the unit The set points are protected by a user password See Startup Adj...

Страница 9: ...should disconnect electric power and interchange any two of the branch circuit wires at the unit input lugs Torque the connectors as discussed earlier Do not move any factory installed wires 4 When ai...