Thermomax SA132 Скачать руководство пользователя страница 10

9

3.

Programming an internal PABX telephone exchange through Direct Inward
System Access (DISA) facility

 

 

 

 

 

 

 

 

6

 →

 

Sequence of telephone number
      (Select only one key)

 

 

7

 −−− 

 

 → 

 -------------------- 

Telephone Number

    Waiting for transfer

 

 

 

 

→ 

!

 

Extension

 Deferred

Number

  Playing

4.

Connected to PABX system or ISDN switcher
If the Autodialer / QuickDialer is connected to an internal PABX telephone
exchange or ISDN switcher, a prefix digit (e.g. 9) is normally required before
an outside line can be obtained.

If the prefix dialing function is activated, the Autodialer / QuickDialer will dial
the first digit (prefix) entered for every telephone number, and then start dial

tone detecting function.  To activate this function, enter 

0

.  To disable the

function, enter 

.  The setting is done as follows:

 

 

9

 →

 

 

 

 

0

 →

 

  Prefix

  (select only one key)

Before entering the telephone number (“27654321” for the example below),
press “9” for the dial output prefix.

 

 

 

 

 

 

 

 

6

 →

 

Sequence of telephone number

         (select only one key)

 

9

→ 

 

7

6

 

 

 

 

 

 →

 

     Prefix

       Telephone Number

SENDING A TEST CALL
It is possible to send one test call by selecting one of the telephone
numbers to call.

 

 

 

 

 

 

 

 

6

 →

 

Sequence of telephone number

(select only one key)

The telephone number of the test call will be dialed only once whether the
line is busy or not.

Содержание SA132

Страница 1: ...AUTODIALLER QUICKDIALLER SA132 INSTRUCTION LEAFLET ENGLISH www Thermomax Group com...

Страница 2: ...CONTENTS 1 SETUPATAGLANCE 2 2 FOREWORD 3 3 INSTALLATION 4 4 KEYPAD AND INDICATORS 6 5 SETTING UP THE UNIT 7 6 TROUBLE SHOOTING GUIDE 12 1...

Страница 3: ...essage Playing Duration Reset the System Speak into microphone for 20 seconds max 5 0 1 2 3 4 50 sec 70 sec 90 sec 110 sec 8 1 2 3 4 Duration Select only one key 8 1 2 3 4 Sequence of telephone number...

Страница 4: ...played during the phone calls The Autodialer QuickDialer can be programmed to call telephone units mobile phones pager and DISA Direct Inward System Access facilities Features Built in terminal block...

Страница 5: ...ckDialer s phone line socket Connect the other end of the telephone line to the phone line socket on the wall See Fig 2 Fig 2 CONNECTING TO POWER SOURCES The Operating Voltage of the Autodialer QuickD...

Страница 6: ...N C trigger input to the alarm N C output of the Thermomax unit 4 Connect the Battery Backup System to the mains and switch on Please refer to the set up instructions supplied with the Battery Backup...

Страница 7: ...D will flash once on the second press of this key the Yellow LED will flash twice and on the third press of this key the Yellow LED will be on for 1 5 second indicating the completion of a programming...

Страница 8: ...ess the key to stop recording 2 Playing Back Message Once the phrases have been recorded by the Autodialer QuickDialer they can be played back through the loudspeaker of a parallel connection telephon...

Страница 9: ...playing setting the Autodialer QuickDialer will try to determine the tone within 7 seconds after dialing the number If it is ring back tone the Autodialer QuickDialer will start playing the messages...

Страница 10: ...Autodialer QuickDialer will dial the first digit prefix entered for every telephone number and then start dial tone detecting function To activate this function enter 0 To disable the function enter...

Страница 11: ...trigger occurs while the previous dialing procedure has not been completed the Autodialer QuickDialer will regard it as the same activation If the triggered zone remains in its triggered state after t...

Страница 12: ...attempts When more than one telephone number is stored the Autodialer QuickDialer will dial in accordance with the order If the number being dialed is engaged the Autodialer Quickdialer will try the...

Страница 13: ...key is connected to the control panel is faulty Yellow LED will 1 Memory selected 1 Select the correct memory not stop flashing incorrectly Green LED does 1 Telephone line is not 1 Check that the Line...