SAFETY THERMOSTAT: 
 

Located within the control enclosure, and not accessible to the operator, is a safety 
thermostat set turn the element off when the temperature rises above 65ºC.   
 
 

ELECTRICAL - POWER LEAD (at rear) 
 

A removable mains power lead with a three pin plug and right angle female IEC 
socket is supplied for connection between the male IEC socket located at the side of 
the bath, and a ten (10 Amp general Purpose Outlet) (G.P.O.)

 

 

 

OPERATION 
 

WARNING: 1. 

To avoid injury do not use flammable solvents in this 

bath, as fire or explosion may result. This bath contains components 
that may ignite such materials. 

 

 

WARNING: 2. 

Do not introduce water into the well (it is not a bath) as 

it may result in component failure. 

 

 
 

OPERATING THE FLOTATION BATH: 

 

1)  Ensure that the bath is located as previously described, refer to the index, 

LOCATION, Place the glass dish into the well and fill it with water to a 
maximum depth of 40mm. 

 

CAUTION:

 Ensure that the ventilation for the 

rear cooling fan are not obstructed. 

 
 

2)  Place the main switch in the ON position (reset), and immediately the 

controller will be activated.  

 

3)  The temperature controller is a Brainchild BTC901 analogue instrument. Each 
division on the temperature scale represents 2ºC. Turn the pointer to the desired 
temperature and allow sufficient time for the water in the dish to reach the 
operating temperature (55ºC for most waxes). The lid may be in place to speed 
up heating.

 

 

Warning:

 Contact with hot fluid of the bath may 

result in personal injury. Ensure appropriate 
protective equipment and procedures are 
applied at all times. 

 

4)  When the set temperature is reached, remove the lid (cover), and allow time 

for the temperature to stabilise again. Adjust the temperature if necessary. 

                                                      
 

5)

  

To turn on the viewing light, simply press the light switch and release, the fluorescent 

light will then be illuminated. To turn off the light press and release the light switch again.

 

 

 

 

Содержание TFB-1

Страница 1: ...fic Equipment Pty Ltd ABN 80 000 859 129 10 12 Ross Place Wetherill Park NSW 2164 P O Box 6862 Wetherill Park DC NSW 1851 Phone 02 9604 3911 International 61 2 9604 3911 Fax 02 9725 1706 International...

Страница 2: ...rts apply when there is a Possibility of personal injury Caution alerts apply when there is a Possibility of damage to the Equipment To maintain safe operation of this equipment be aware of the ALERT...

Страница 3: ...king material check that it is complete Assemble the components and inspect for damage Retain the packaging materials until the equipment has been thoroughly tested Notify the detail of any damage wit...

Страница 4: ...temperature is set at the temperature controller The temperature sensor is located within a spring clip and is designed to rest against the glass insert dish The signal from the temperature sensor is...

Страница 5: ...y be removed for cleaning The external case and the stainless steel surfaces may be wiped clean using a damp soft cloth Note Stainless steel is under most conditions extremely resistant to corrosion T...

Страница 6: ...icate an electrical fault exists Switch off the power on consult a qualified technician TEMPERATURE CONTROL SENSOR This is a Brainchild BTC901 analogue control scaled a 2 C increments and has been con...

Страница 7: ...to the well and fill it with water to a maximum depth of 40mm CAUTION Ensure that the ventilation for the rear cooling fan are not obstructed 2 Place the main switch in the ON position reset and immed...

Страница 8: ...ng the preceding clause and to the extent permissible by law the liability of Thermoline is limited in relation to the warranted product and at the option of Thermoline to replacing the product or the...

Отзывы: