35
2.
FUNCTION STAND-BY SET OFF
In the case that function STAND BY is not activated (OFF) , and that connection for
the room thermostat is not overbridged, stove will always work in power 1 no matter
which power is set.
In the case that function STAND BY is not activated (OFF), and connection for room
thermostat is overbridged (set in the factory) stove will work in the power chosen by
the user, and when desired temperature is reached will go into modulation mode.
Stove will shut down only if the temperature in the stove is 80 degrees C, and will start
again when temperature drops down below desired temperature.
6.3.5.2
STAND BY mode with room thermostat connected
1.
FUNCTION STAND-BY SET ON – room thermostat shuts down
stove
When room thermostat sends signal that desired temperature in the room is reached
(contact is open/temperature is reached) stove will shut down after 2 minute (factory
settings- in the case that temperature in the room changes all to prevent constant
turning on and off of the stove) on display is written
tOFF-WAITING REQUEST.
When room thermostat gives signal that room temperature is low (contact closed/
temperature needs to be reached) stove will start ignition and on display is written
tON.
Remark:
Stove functioning primarily depends on temperature of the water inside of
stove and factory settings inserted. If stove is in state of
WAITING COOLING
(water
temperature is reached), eventual request of the thermometer will be ignored.
2.
FUNCTION STAND-BY SET OFF – room thermostat gives signal
to the stove to work in POWER 1
In the case that function STAND BY is not activated (OFF) stove will work in power
chosen by the user and when desired temperature is reached stove will modulate (will
not shut down but working power will change to lowest).
Stove will shut down only if temperature of the water in the system is 80 degrees C,
and on display is written
WAITING COOLING
. Stove will start again when
temperature in the system drops down below set temperature.
6.3.6
Option Buzzer
B
UZZER
is used in the case that user want to hear sound signal from the stove in
the case of activated alarm ( set ON ), or without sound signal ( set OFF ).
Option BUZZER is activated by pressing of button SET, and after that with
buttons 5 or 6 we choose item
MENU 05- OPTION BUZZER.
By pressing of the button
SET
choice
ON
or
OFF
is opened (with buttons
1
or 2
we are selecting option and confirmation is done by pressing
SET
).
Содержание INTERIO
Страница 2: ......
Страница 6: ...5...
Страница 14: ...13...
Страница 24: ...23 5 Connection 5 1 Hydraulic schemes for connection...
Страница 25: ...24 5 2 Electrical wiring diagram...
Страница 30: ...29 6 3 Schematic representation of the menu control By pressing button SET we enter general menu...
Страница 31: ...30...
Страница 32: ...31 6 3 1 Clock adjustments Clock adjustments can be done on following way...
Страница 34: ...33 Sheme 2 Sheme 3 Sheme 4...
Страница 50: ...49...
Страница 51: ...50 ThermoFLUX d o o Bage br 3 Jajce Bosnia and Herzegovina Tel fax 387 30 657 100 www thermoflux ba 2018...