If the chimney has a too high underpressure (over 20 Pa), the regulation can be
achieved in different ways. One way is to easily open the cleaning door. We
recommend to install the draft regulator.
The pellet stove can not be connected:
To the chimney or the flue pipe to wich another heat source is connected (gas
boiler, pellet boiler, etc.)
Ventilation system
When connecting the pellet stove to the chimney, smoke pipes with a diameter of
80mm and temperature-resistant gakets must be used. It is recommended to install a
T-piece with revision or a knee after the chimney outlet, and a piece of flue pipe of a
length of min. 0.5m and then connect the stove to the chimney. It is not recommended
to connect directly between the stove and the chimney without flue pipes. It is also
not recommended to attach a connection of the flue pipes on the left or right, which
means you do not make knee in the flue pipes in the sides.