![THERMODYNE 742HW Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/thermodyne/742hw/742hw_installation-and-operation-manual_1105537016.webp)
— 16 —
15. Repeat steps 12-14 until unit is completely full
of fluid.
16. Once unit is completely filled, reattach the
heater tank cap and the powerhead lid.
NOTE: If ADD FLUID light is on, add fluid to
reservoir tank until light goes out.
17. Allow the unit to heat until set temperature is
reached.
18. Once set temperature is reached, place the
power switch in the OFF position and let the
unit cool down to at least 100°F.
19. Turn unit back on, and if ADD FLUID light is
on again, add fluid to reservoir tank until light
goes out.
NOTE: Steps 17-19 are very critical in order to
purge any trapped air from the unit.
CLEANING THE DRY WELL
With the wells empty, wipe any debris or loose
food from dry well section with rag. (Be Careful,
well section can still be hot).
Holding Pan
Figure 15: Cleaning the Dry Well
Содержание 742HW
Страница 18: ...18 SCHEMATIC WIRING DIAGRAM...