8
40.021.119 - rev. 00 - 2019
IMAC 4000 GAS US
English
Caution
Do not switch on the convector heater if
there is no fuel, or if the connected fuel
tank is empty.
3. Set the room thermostat.
The convector heater will produce hot air
after some seconds.
To start up the ventilation:
1. Turn the rotary switch to position 1 of 2, see
fig. 5.
The fan will start up slowly.
4
USE
4.1
During operation
Hot
Do not touch the flue stack or blower
outlet! The flue stack and blower outlet
get hot during operation!
4.2
Switch off
Switch off heating:
1. Turn the rotary switch to position “0”.
The magnet valve(s) close(s) and stop(s) the
fuel supply.
The convector heater stops burning.
Caution
After switching off the convector heater,
the ventilator will continue to run. The
ventilator will cool down the convector
heater to prevent damage by
overheating. The ventilator will
automatically stop.
The fan can start again without warning.
2. Shut off the fuel supply.
Switch off the cooling:
1. Turn the rotary switch to position “0”.
The ventilator will automatically stop.
4.3
Transport after use
1. Switch off the convector heater and wait until
the fan has stopped completely.
2. Switch off the power supply.
3. Remove the connection from the room
thermostat and place the cap on the
thermostat connection.
4. Remove the air hoses.
5. Remove the flue.
6. Remove the fuel connection.
Caution
Only use natural gas of the family I2H
and propane of the family 13P
4. Make sure there is sufficient distance between
the wall and the air inlet.
Minimum distance is 1 m.
5. Ensure that the heated air is allowed to flow
freely. The minimum distance between the
outlet and any obstacle is 5 m.
6. Check the ventilation surface: per kW, a
surface area of 25 cm2 is required.
7. Check the connection of the room thermostat.
Do not remove the cap if you do not use a
room thermostat.
To connect the room thermostat, remove the
cap.
8. Install the flue (1 m and a rain cap).
9. Make sure the convector heater is switched off.
See fig. 5.
10. Check the supply voltage: see identification
plate.
11. Connect the convector heater to the socket of
the electric power supply.
The indicator light “Panel live” is on.
12. If necessary, press the reset switch.
13. Reset the thermostat, see fig. 5.
Installation of this appliance at altitudes above
2000 ft (610 m) shall be in accordance with local
codes, or in the absence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
or National Standard of Canada, Natural Gas and
Propane Installation Code, CSA B149.1.
3.3
Start up
To start up the heating:
Open the shuttoff valve (Q).
1. Switch the rotary switch to position 2.
The burner starts up with low capaity and
automatically goes to high capacity.
The convector heater will produce heat and
will switch on the fan after a short while.
2. Switch on the room thermostat.
To start up the ventilation:
1. Switch the rotary switch to position 1.
See fig. 5. The fan will start up.
Содержание IMAC 4000 GAS US
Страница 1: ...IMAC 4000 GAS US USER MANUAL...
Страница 2: ...2 40 020 950 rev 01 2019 IMAC 4000 US A B C D E F G H I J K L M N O P Q R 1 2 3 4...
Страница 3: ...3 40 020 950 rev 01 2019 IMAC 4000 US 5 7...
Страница 4: ...4 40 020 950 rev 01 2019 IMAC 4000 US Language English 5...
Страница 14: ...14 40 021 119 rev 00 2019 IMAC 4000 GAS US English Date Description Maintenance or Failure Action by A...
Страница 15: ...15 40 021 119 rev 00 2019 English IMAC 4000 GAS US Date Description Maintenance or Failure Action by...
Страница 17: ...17 40 021 119 rev 00 2019 English IMAC 4000 GAS US...
Страница 18: ...18 40 020 950 rev 01 2019 IMAC 4000 US...