6-14
DB-066 E
RadEye PRD-ER
Iw/Tr/Ff 06.07.2015
If the RadEye PRD is mainly used as an alarm device wearing
at the belt, it is recommended to set an alarm latching time of
10s. This is useful to notice short exposure events.
The software control of the energy ratio sensitivity allows a
fine tuning of the NBR-alarm (see chapter 4.8). E.g. selection
of a high sensitivity for high energy radiation can be used to
distinguish between material containing predominantly Thori-
um (high energy- indication) or natural Uranium (balanced
indication). In most cases both sliders can be set to high sensi-
tivity without false alarms in a natural environment.
6.4.4
Bluetooth
Figure 6-9: Bluetooth configuration
Содержание RadEye PRD-ER