Thermo Scientific

ROSS Ultra, ROSS Ultra Triode and ROSS pH Electrodes 

|

 

5

Thermo Scientific Orion

ROSS Electrodes

ROSS electrodes provide precise pH measurements and measurement 

stability regardless of temperature changes or sample composition. 

ROSS Sure-Flow Electrodes 

ROSS

 

Sure-Flow electrodes incorporate a free-flowing junction that is 

easy to clean and never clogs. These electrodes are ideal for dirty or 

viscous samples that clog traditional electrodes.

ROSS Semi-micro Electrodes 

ROSS semi-micro electrodes are designed for applications where 

sample volume is limited and can take measurements in samples of 0.2 

ml volume. They are available with chemically-resistant glass (6 mm 

tip) or epoxy (8 mm tip) bodies, Sure-Flow junction and ROSS Ultra 

long-life models.

ROSS micro pH Electrodes

ROSS micro pH electrodes have been designed to measure

extremely small samples. The measuring tip is 3 mm in diameter and

40 mm long. The minimum depth of immersion is 4.5 mm and the

minimum sample size is 15 μL in 384 well plates.

Required Equipment

1.  Thermo Scientific

 Orion

 

V

ersa

 s

tar

, Thermo Scientific

 Orion

 

Star

 A300 series, Thermo Scientific

 Orion

 

Star

 A200 series, 

Thermo Scientific

 Orion

 

Star

 A100 series or Thermo Scientific

 

Orion

™ 

D

ual

 s

tar

 meter with pH measurement capability, 

such as the 

V

ersa

 s

tar

 benchtop meter with pH module, Star 

A211 pH benchtop meter or Star A321 pH portable meter; 

except 8107BNURCA, 8157BNURCA and 8302BNURCA Triode 

electrodes which are designed for use with a meters which support 

a thermister with a 30K NTC curve and have an RCA plug, such as 

the Five and Seven Series 

METTLER TOLEDO

 pH meters.  

ROSS electrodes can be used on any pH meter with a BNC 

connection. The electrodes can also be used on meters with 

a variety of inputs when an adapter cable is used. Visit www.

thermoscientific.com/water for details.

2.  Orion ROSS Ultra, and ROSS Triode electrodes.

• 

 The 8302BNUMD, 8107BNUMD, 8107UWMMD, 8157BNUMD 

and 8157UWMMD pH/ATC Triode electrodes have a 

temperature connector that is compatible with Orion Star A 

series, 

V

ersa

 s

tar

 and 

D

ual

 s

tar

 pH meters.

• 

The 8107BNURCA, 8157BNURCA and 8302BNURCA pH/

ATC Triode electrodes have a temperature connector that is 

compatible with meters which support a thermister with a 30K 

NTC curve and have an RCA plug, such as the Five and Seven 

Series

 METTLER TOLEDO 

pH meters. 

3.   ROSS fill solution, Cat. No. 810007.  

Note: 

 Do not use any fill solution that contains silver, as silver 

will damage ROSS electrodes.  

Содержание Orion ROSS

Страница 1: ...ROSS Ultra ROSS Ultra Triode and ROSS pH Electrodes 263745 001 Revision B November 2014 Thermo Scientific Orion U ser Manual...

Страница 2: ......

Страница 3: ...ode Calibration 10 General Calibration Procedure 10 One Buffer Calibration 10 Two Buffer Calibration 11 pH Measurements 12 Electrode Storage 12 Electrode Maintenance 12 Electrode Cleaning Procedures 1...

Страница 4: ...s are three to five times more precise than those obtained with conventional electrodes Over the lifetime of the electrode ROSS reference potential drifts less than an average 0 12mV per day which cor...

Страница 5: ...ientific Orion Star A200 series Thermo Scientific Orion Star A100 series or Thermo Scientific Orion Dual Star meter with pH measurement capability such as the Versa Star benchtop meter with pH module...

Страница 6: ...3 The electrode may arrive with the chamber partially filled with electrolyte solution Please fill the chamber with electrolyte solution before use Uncover the fill hole by removing the tape and add...

Страница 7: ...an adequate flow rate the level of fill solution must always be above the reference junction and at least one inch above the sample level The fill hole should remain open whenever the electrode is in...

Страница 8: ...on aqueous solutions and solutions that contain organic solvents A minimum of 20 water must be present in the sample for the best measurement results If there is a great deal of drift when using the R...

Страница 9: ...a uniform rate Place a piece of insulating material such as polystyrene foam or cardboard between the magnetic stir plate and beaker to prevent measurement errors from the transfer of heat to the sam...

Страница 10: ...the meter is set to automatically recognize the pH buffer at the measured temperature and an ATC probe is used you do not need to manually adjust the pH values of the buffers One Buffer Calibration 1...

Страница 11: ...rode into the first buffer When the reading is stable set the meter to the pH value of the buffer at the measured temperature Refer to the meter user guide for a detailed procedure Table 1 provides pH...

Страница 12: ...flush it with fresh ROSS fill solution and refill the chamber with fresh ROSS fill solution Electrode Cleaning Procedures General Cleaning We offer a variety of Orion pH cleaning solutions for your c...

Страница 13: ...n Cat No 910001 for at least one hour Cleaning Solutions Cat No 900021 WA pH cleaning solution A for removing protein contaminants Cat No 900022 WA pH cleaning solution B for removing bacterial contam...

Страница 14: ...C probe are placed into a sample that varies significantly in temperature the readings can drift for two reasons First the temperature response of the electrode and temperature probe may not be simila...

Страница 15: ...m precision a three point temperature calibration is recommended Do not perform a one point temperature calibration if measured solutions will be below 20 C The following tables illustrate the expecte...

Страница 16: ...s and at higher temperatures Because the pH membrane is composed of special low sodium error glass error due to sodium is negligible when measuring at pH values less than 12 When measuring at pH value...

Страница 17: ...lectrode into fresh pH 4 buffer When the reading is stable record the mV value of the pH 4 buffer The mV value should be in the range of 150 to 210 mV 4 Calculate the absolute mV difference between th...

Страница 18: ...Mercury Hg Cadmium Cd Sensor body with cable assembly X 0 0 Plastic hardware 0 0 0 Part Name Toxic or Hazardous Substances and Elements Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybromi...

Страница 19: ...combination pH electrode with epoxy body and semi micro tip waterproof BNC connector 8135BNUWP ROSS Ultra combination pH electrode with epoxy body and flat surface tip waterproof BNC connector 8156BN...

Страница 20: ...ctrode with epoxy body waterproof BNC connector 8165DN ROSS Sure Flow combination pH electrode with epoxy body E DIN waterproof connector 8172BNWP ROSS Sure Flow combination pH electrode with glass bo...

Страница 21: ...scientific com water for additional accessories buffers and buffer sizes Specifications pH Range 0 to 14 pH pH Precision 0 01 pH Temperature Range 0 to 100 C ROSS Ultra Triode Temperature Accuracy 1 C...

Страница 22: ...8102BN 8104BN 8135BN 815600 8162SC 8165BNWP 8172BNWP 8302BNURCA 8107BNURCA 8157BNURCA 120 mm length 12 mm diameter 8103BNUWP 8103BN 8103SC 165 mm length 95 mm tip length 6 mm tip diameter 8115BNUWP 8...

Страница 23: ......

Страница 24: ...moscientific com water Netherlands Tel 31 020 4936270 info water uk thermo com China Tel 86 21 68654588 wai asia thermofisher com India Tel 91 22 4157 8800 wai asia thermofisher com Singapore Tel 65 6...

Отзывы: