Sarasota 200 Ultrasonic Multipath
Flowmeter
Appendix 1 GAFA PC Software Page A1-11
Thermo Fisher Scientific
APPENDIX 1 GAFA PC SOFTWARE
A1.4.2 Channel Configuration
A1.4.2.1 (Channel Configuration) Channel
Notes
•
If a “Fixed Datum” is used, the height of the bed of the channel must be specified relative
to the fixed datum via this screen. Also all path heights and depth offsets must be
specified relative to the fixed datum via the “Channel Configuration – Velocity Path” and
“Channel Configuration – Level” screens A1.4.2.2 and A1.4.2.3.
•
If the “Mean Bed Level” datum is used, the Sarasota 200 sets the “Bed Level” to zero. All
path heights and depth offsets must be specified relative to the Mean Bed Level via
“Channel Configuration – Velocity Path” and “Channel Configuration – Level” screens
A1.4.2.2 and A1.4.2.3.
•
“Level Arbitration” is the allowable difference between individual level measurements.
•
“Fire Sequence” is normally Simultaneous. “Alternate” should only be used if there is a
risk of reflections from a transducer being confused with signals being transmitted by its
partner. “Alternate” will slow the operation.
•
The top and bottom slice factors are entered via this screen. Refer to Section 1 of this
manual.
•
The maximum and minimum water velocities are entered via this screen. If any path
measures a velocity outside the specified range it is considered faulty and excluded from
the flow calculation.
•
Click on “Write To Gauge” to confirm selections to the Sarasota 200 or “Cancel” to
abandon.