Appendix 1 GAFA PC Software Page A1-5
Thermo Fisher Scientific
APPENDIX 1 GAFA PC SOFTWARE
A1.3.3 (View) Flow Meter Status
Notes
•
“Software IDs” are the issue numbers of the software loaded on the system cards
•
“CPU Power Rails” show the values of the internal supply voltages.
•
“Status” conditions are red for a fault and green for OK.
•
For “Channel” status, “Level” is red if all the levels are faulty and “Path” if all the paths
are faulty. These are “fatal” conditions that could prevent flow being calculated. Under
these conditions, a flow figure could still be estimated using the flow estimation table,
See A1.4.2.5
•
“Relay Status” indications depend on conditions as set on the “Station Configuration –
Relay” screen.
•
Click on “Refresh” to update displayed data.
•
Relays may be reset on this screen or alternatively on the “Station Configuration -
Relays” screen A1.4.1.3.
•
Click on X or Cancel or press the escape key to return to the Main screen.