14  |   Emerald Bluetooth Enabled Wireless Remote Sensors

Compatible Sensors for Smart-Vue Pro Duo / Quatro Data Logger

5. Wait until the unpairing process is complete which may 

take a few seconds then tap 

OK

. The wireless remote 

sensor is removed from the list.

Resetting a Wireless Remote 

Sensor’s Battery Counter 

To reset the Emerald wireless remote sensor’s battery 
counter (only after removing or replacing batteries), use the 
Reset battery option on your Smart-Vue Pro data logger. 

To reset the wireless remote sensor’s battery counter:

1. Tap the menu icon 

 

 Sensors 

 Remote sensors.

2. Enter your PIN code and tap 

OK

.

3. Tap Reset battery.

4. Sensors that are currently paired with the Smart-Vue Pro 

data logger are displayed. Tap to select the serial number 
of the sensor whose battery you have changed and wish 
to reset.

Figure 11. Resetting a wireless remote sensor’s 

battery counter

5. Tap 

OK

 to confirm that you want to reset the battery 

counter.

6. Tap again on 

OK

 to return to the remote sensors menu 

when done. 

Swapping Sensors

The purpose of the Smart-Vue Pro Swap sensor feature is to 
replace a Bluetooth wireless remote sensors while it is 
currently being used for data logging.

Wired Sensors

With your Smart-Vue Pro data logger, you may directly swap 
wired sensors that are physically connected to your data 
logger such as for recalibration or to replace damaged cables. 
Wired sensors may be replaced at any time whether data 
logging is running or not. You must ensure that the existing 
and replacement sensors are identical in type. 
The process is completely transparent and guarantees 
continuity while avoiding down-time or interruptions.

Emerald Wireless Remote Sensors

With wireless remote sensors connected via Bluetooth, you 
must use the Smart-Vue Pro data logger interface to swap 
wireless remote sensors. To do this, the following conditions 
must be met:

Data logging must be currently running using the wireless 
remote sensor you want to replace.

The new wireless remote sensor must also be paired with 
the Smart-Vue Pro data logger (up to four remote 
sensors may be paired with Quatro data logger).

The two wireless remote sensors must be of the same 
type. 
For example, both must be the same type of Emerald 
internal or external (with Pt100 probe) sensor.

Note: 

When Four (4) maximum wireless remote sensors are 

paired with the Smart-Vue Pro data logger, data logging 
needs to be stopped for at least one wireless remote sensor 
in order to use the swap functionality.

To swap sensors:

1. Tap the menu icon 

 

 Sensors 

 Remote sensors.

2. Enter your PIN code and tap 

OK

.

3. Tap 

Swap sensor

.

4. Tap to select the sensor to replace and tap 

OK

 to 

confirm.

CAUTION: 

Only perform this action if you actually 

install a new battery in your Emerald wireless 
remote sensor module.

CAUTION: 

The above instructions only affect the 

battery contained in Emerald wireless remote 
sensors, not the Smart-Vue Pro data logger itself.

Содержание Differential Pressure Sensor

Страница 1: ...e Sensors for Smart Vue Pro Duo Quatro Data Logger Emerald Wireless Remote Sensor Triple CO2 Temperature and Humidity Sensor Differential Pressure Sensor Supplemental User Guide 331942H01 Revision B 1...

Страница 2: ...med by qualified service personnel Material in this manual is for informational purposes only The contents and the product it describes are subject to change without notice Thermo Fisher Scientific ma...

Страница 3: ...s Remote Sensors 10 Wireless Remote Sensor Calibration 10 Key Specifications 11 Inserting the Battery into your Emerald Sensor 11 Activating an Emerald Wireless Remote Sensor 11 Mounting your Emerald...

Страница 4: ...Smart Sensor 22 Overview 22 Usage 22 Tube Placement 23 Key Specifications 24 Placement and Assembly 24 Velcro location on Extension box 25 Appendix 1 Troubleshooting 26 Appendix 2 Emerald Battery Life...

Страница 5: ...ct s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to a person CAUTION This product contains two non rechargeable 3 6V lithium batteries Plugging the device into...

Страница 6: ...TION Do not use this device in explosive or hazardous environments CAUTION Do not expose your device to any extreme environment where the temperature or humidity is high Such exposure could result in...

Страница 7: ...and contact OCEASOFT technical services Battery Warning CAUTION This product contains a lithium battery Make sure you respect polarity when inserting batteries into OCEASOFT devices Reversing polarit...

Страница 8: ...subject to the following two conditions 1 This device may not cause interference 4 Certifications and Compliance 2 This device must accept any interference including interference that may cause undes...

Страница 9: ...is in compliance with the EU Directive 2011 65 EU Restriction of the Use of Certain Hazardous Substances in Electronic and Electrical Equipment and the amendment of EU 2015 863 Do not dispose of this...

Страница 10: ...imum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropi...

Страница 11: ...d other relevant provisions of the Waste Electrical and Electronic Equipment Directive 2012 19 EU WEEE Directive Environmental Protection RoHS Compliance Respect local regulations concerning disposal...

Страница 12: ...potentially expose you to chemicals including lead which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov Respect local regulations concerning disp...

Страница 13: ...remote sensor Triple CO2 Temperature and Humidity sensor Differential pressure sensor The focus in this document is mainly on physical hardware aspects of the Smart Sensors listed above Where to go f...

Страница 14: ...s with up to two active wireless remote sensors on Smart Vue Pro Duo or up to four on Smart Vue Pro Quatro For the Smart Vue Pro data logger to detect your nearby Emerald wireless remote sensor you mu...

Страница 15: ...remote sensor you must first activate the sensor as described here 1 Place the strong side of the magnet the side without the adhesive tape in the circular recess on the back of the Emerald sensor an...

Страница 16: ...Adhesive Tape You may also choose to mount the Emerald sensor using the provided adhesive tape Note Clean the magnet before using the adhesive tape on it Using Wireless Remote Sensors with your Data L...

Страница 17: ...o another Smart Vue Pro data logger cannot be paired 6 Tap the sensor and confirm the connection by tapping OK 7 Wait until pairing is complete which may take a few seconds Once pairing is successful...

Страница 18: ...place damaged cables Wired sensors may be replaced at any time whether data logging is running or not You must ensure that the existing and replacement sensors are identical in type The process is com...

Страница 19: ...y the Smart Vue Pro web application Wireless Remote Sensors in Smart Vue Pro Web Application This section provides additional information regarding the use of wireless remote sensors in the Smart Vue...

Страница 20: ...data logger via the data logger menu displays the wireless remote sensor with the Bluetooth logo as shown here Figure 15 Wireless remote sensor shown on data logger Wireless Remote Sensor in the Senso...

Страница 21: ...o and is displayed purely for future use Wireless Remote Sensor Battery Indication The wireless remote sensor battery percentage is shown under Smart Tracker Pro as below Figure 20 Wireless remote sen...

Страница 22: ...inside the incubator Remove the CO2 temperature and humidity sensor from inside the incubator during decontamination procedures which may expose the sensor to damaging heat environment CAUTION Failure...

Страница 23: ...90 RH non condensing for indoor use Contact your Thermo Fisher Scientific representative for details regarding sensor accuracy drift and calibration Placing the Sensor and Smart Vue Pro Data Logger Fo...

Страница 24: ...cable into the Smart Sensor extension and the Smart Vue Pro data logger 2 this cable provides power to the Smart Vue Pro data logger Figure 27 Power connections for triple sensor unit 5 Connect the S...

Страница 25: ...uting sensor cables avoid direct contact with or close proximity of sensor cabling with any high voltage wiring Cabling should be placed with no less than a minimum of 2 inches 50 mm distance from hig...

Страница 26: ...placed outside the cleanroom so that people know it is safe to enter as shown in these two examples 1 High pressure cleanrooms such as vaccine and organ transplant laboratories in which the ambient pr...

Страница 27: ...he display A common way to use this sensor is therefore to plug the tube onto the high connector and under normal conditions obtain positive values when monitoring high pressure cleanrooms and negativ...

Страница 28: ...te or connector on the data logger 2 Clip the Smart Sensor extension firmly onto the bottom of the Smart Vue Pro data logger Figure 38 Slide the smart sensor extension onto Smart Vue Pro data logger 3...

Страница 29: ...Compatible Sensors for Smart Vue Pro Duo Quatro Data Logger Differential Pressure Smart Sensor 25 Velcro location on Extension box Figure 39 Velcro location...

Страница 30: ...in the Smart Vue Pro web application What should I do During pairing the Smart Vue Pro data logger downloads calibration parameters from the wireless remote sensor If wireless remote communication fa...

Страница 31: ...e user tries to unpair the remote sensor which is in out of range from the Smart Vue Pro data logger a message is displayed on the Smart Vue Pro data logger to reset the remote sensor to finish unpair...

Страница 32: ...a Logger Does the Emerald device send a low battery alert to the data logger Emerald low battery indication is not shown on Smart Vue Pro Duo Quatro data logger but Emerald low batery status level are...

Страница 33: ...conditions Wireless remote communications Bluetooth connections consume battery power However it is worth noting that the Smart Vue Pro data logger reads Bluetooth advertising frames from the Emerald...

Страница 34: ...thermofisher com WEEERoHS Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2012 19 EU in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE marcato col...

Страница 35: ...e 33 2 2803 2180 Germany international 49 6184 90 6000 Germany national toll free 0800 1 536 376 Italy 32 02 95059 552 Netherlands 31 76 579 55 55 Nordic Baltic CIS countries 358 9 329 10200 Russia 7...

Отзывы: