1.3 Control
Unit
1.3.1
Model 20-35-NM-F (Field Mount Version)
The Control Unit is housed in an enclosure with green (“normal”) and red (“alarm”)
indicating lights on the front cover. An adjustable selection of 1, 2, 4, or 6 seconds
of time delay in the control unit circuit will prevent false or premature contact
transfer caused by momentary tilting of probe.
Tilt Probe alarm position: Two SPDT output contacts for connection to external
alarms and/or controls.
Probe failure or supply short: One normally open (NO) contact.
SPECIFICATIONS:
Power Requirements
Voltage:
115/230 VAC +/- 10%, by selector switch
Frequency: 50/60Hz
Consumption: 7VA
Fusing:
(F1) 0.05A SB Type T (F2) 0.1A SB Type T
Outputs
Alarm:
Two (2) SPDT contact.
Rated at 10 Amp at 115/230 VAC or 7 Amp at 30 VDC non-
inductive
Probe Fault or Supply Short: One (1) NO contact 115/230 VAC 2
Amp, 24VDC 3 Amp.
Time Delay:
Adjustable 1, 2, 4, or 6 seconds.
Dimensions:
See Figure 2-1
Humidity:
50 to 80%
Altitude:
Up to 2000m
Temperature Rating:
-40°F(-40°C)
≤
Ta
≤
+122°F(+50°C)
Protection:
NEMA 4, Optional NEMA4X Stainless Steel
Pollution Degree:
2
Installation Category:
II
Содержание 20-35-NM-DIN
Страница 2: ...ii ...
Страница 6: ...vi ...
Страница 11: ...xi ...
Страница 18: ...xviii PROBE Models 20 54 NM SS 20 52 NM 20 59 NM 20 55 NM P TAG MARKING CE Certification CE ...
Страница 24: ...1 6 ...
Страница 28: ...2 4 Figure 2 3 Probe Model 20 54 NM SS Stainless Steel Probe Dimensions are inches and mm ...
Страница 29: ...2 5 Figure 2 4 Probe Model 20 52 NM Heavy Weight Probe Dimensions are inches and mm ...
Страница 30: ...2 6 Figure 2 5 Probe Model 20 59 NM Steel Probe Dimensions are inches and mm ...
Страница 31: ...2 7 Figure 2 6 Probe Model 20 55 NM P Plastic Probe Dimensions are inches and mm ...
Страница 33: ...2 9 Figure 2 8 Control Unit Model 20 35 NM F Internal Layout ...
Страница 35: ...2 11 Figure 2 10 Control Unit Model 20 35 NM DIN Internal Layout FAULT ...
Страница 36: ......
Страница 38: ...3 2 Low Application Examples Typical Plugged Transfer Chute Alarms ...
Страница 50: ...7 3 7 3 Probe Label The following figure shows where the labels are positioned on the Tilt Sensor Probes ...