Condenser Defrost Icon:
Appears when the condenser coil is defrosting and at the same time as the defrost icon (the
unit is in Condenser Defrost mode)
Alarm Icon:
Appears when an alarm condition has been detected by the microprocessor.
Electric Icon:
Appears when the unit is in Electric Standby mode.
Setpoint Icon:
Appears when the setpoint temperature is being shown in the display.
Controller Menu
The DSR II and III controllers have four menus: the main menu, the hour meter menu, the information menu, and the
guarded access menu. Refer to (
Main Menu
To access the main menu, press the Select key. Press the select key to scroll through the menu.
•
The main menu is used to view the alarms, initiate a manual defrost, and modify the set point(s).
Hour Meter
To access the hour meter menu, press and hold the Select key for three seconds. Press the select key to scroll through
the menu.
•
The hour meter menu contains the following times: maintenance hour counter, total unit hours, vehicle compressor
hours, and standby compressor hours. Note:
N
No
otte
e:: The maintenance hour counter is the only resettable counter and must be accessed through WinTrac
™
.
Information Menu
To access the information menu, press and hold the Up Arrow key and the Enter key simultaneously for three seconds.
•
The information menu contains a display test (activates all pixels on the display), displays the software (firmware)
version, the refrigerant type (r-134a or r-4xx), the battery voltage, the high pressure transducer reading, and the
number of compartments (1C for 1 single temp units and 2C for multi-temp units) and unit type (t10, t20, t30, and
t50.)
Installation Menu
To access the installation (guarded access) menu, press and hold the Down Arrow key and the Enter key simultaneously
for three seconds.
•
The installation menu contains menu options that can be set for customer specific applications. These options are
the following: the lower limit and upper limit set points, the set point differential (number of degrees the
temperature can drift from set point before energizing the clutch), the soft start cycle for the compressor (MUST
REMAIN ON FOR ALL UNITS), defrost initiation timer (the time between checking coil for ice), defrost termination
timer, evaporator fans constantly on, the out of range alarm, the hour counter initial value, door switch presence/
polarity, buzzer enabled, temperature units (°F/°C), pressure units (PSI/bar), and the temperature resolution.